background image

1.  Make sure the camera battery is fully charged 

and a SD card is inserted into the camera.        

2.  Pull top housing control knobs up for        

clearance.

3.  Remove Camera Mounting Tray from 

Mounting Plate - Diagram B.

4.  Attach camera and TURN ON.

5.  Gently slide the camera with Mounting Tray 

back into the Mounting Plate. Using your 

thumbs, push against the Mounting Tray until 

it stops sliding forward into the Mounting 

Plate. Give the Mounting Tray an extra push 

to make sure it is properly seated all the way 

forward in the Mounting Plate and no housing 

controls are in the way.

6.  Slide the Hotshoe into the top camera mount until it stops. Turn Hotshoe 

Rotary Lock clockwise to tighten to camera mount - Diagram C, back page.

7.  Make sure Hotshoe cord does not interfere with controls or the housing back 

when closing the housing.

PLEASE  READ  COMPLETELY.  This  Quickstart  Guide  will  give  you  the  basic  information  necessary  to  begin  shooting  underwater                               

photo/video. It is recommended that you also read your Ikelite Instruction Manual and Camera Owner’s Manual. 

6843.72

 

Underwater TTL Housing 

for Sony Alpha a7 II, a7R II, a7S II

Q u i c k s t a r t   G u i d e

IMPORTANT INFORMATION

  This housing requires the addition of a compatible Lens Port for waterproof  

operation. Lens Port not included. Go to ikelite.com for Lens Port options.

Step 1 - INITIAL CAMERA SETTINGS - before placing camera in housing 

INITIAL CAMERA SETTINGS -

 

continued

Step 2 - OPENING THE HOUSING

Lid Snaps have a Lock - Diagram A.

1.  Push Lid Snap Locks forward and lift 

as shown. Open opposing Lid Snaps 

simultaneously. Keep pressure on 

the Lid Snaps so they do not fly open 

quickly. Some Lid Snaps have a lot of 

spring tension once they go over center, 

so keep a firm grip on each Lid Snap. 

Lid Snaps may also be opened one at a 

time. 

2.  Remove the Housing Back. 

Step 3 - INSTALL CAMERA IN HOUSING - Diagram C - back page

IKELITE

Continued on Back Page >>

Push Forward

Lift

Lid

Snap

Lock

Diagram A

Mounting Tray

Mounting Plate

Pull to Remove

Diagram B

-  Your housing is setup to accept the Sony a7R II and a7S II camera models. If 

you are using the a7 II model, remove the existing camera tray marked a7R II 

and replace it with the camera tray marked a7 II. Also, remove the adhesive 

backing from the thin foam frame (included in box) and place the frame over 

the existing foam frame on the housing back. Lastly, remove the washer from  

under the knob for the Mode Dial control.

-  This housing features an integrated TTL circuit that is automatically powered 

by any DS-series strobe. Only Ikelite DS strobes are capable of powering 

the circuitry. Exposure compensation in TTL mode is supported using the 

camera’s built-in control. For manual flash operation, move the switch on the 

back of the housing Tray Mount to the left or “M” position, as noted above the 

switch. 

  SEA&SEA, INON, and Nikonos strobes must be used in manual exposure 

modes only

-  We recommend turning the camera on BEFORE placing it in the housing. 

To turn the camera on AFTER it is placed in the housing, lift and rotate the 

housing ON/OFF knob, so the White Dot is in the 9 o’clock position from the 

back of the housing. Push the knob back down and rotate clockwise to turn 

on. The White Dot will line up with the 2 small dots on the top of the housing 

as the camera is activated. DO NOT continue rotating knob once the camera 

has been activated; doing so could damage the camera switch. To turn the 

camera off AFTER it is placed in the housing, lift and rotate the housing ON/

OFF knob so the White Dot is in the 1 o’clock position. Push the knob back 

down and rotate counter clockwise to turn camera off. The White Dot will 

line up with the 2 small dots on the top of the housing as the camera is being 

deactivated. DO NOT continue rotating knob once the camera has been 

deactivated; doing so could damage the camera switch.

-  Insert a fully charged battery.

-  Set Mode Dial to “A” Aperture Priority. Manually adjust aperture setting to 

achieve the best exposure for your shooting conditions. The shutter speed 

will be locked at 1/30th-1/60th second. If a faster shutter speed is desired or 

you are NOT using an external strobe, set Mode Dial to “M” Manual mode to 

manually adjust both aperture and shutter speed settings.

-  In        MENU settings:

  Set Image Size to highest preferred setting.  

  Set Drive Mode to “Single Shooting”  and Flash Mode to     “Fill-flash.”

  Set Red Eye Reduction to “Off.”

  Set Focus Mode to “Single-shot AF” and Focus Area to “Center.”

  Set AF Illuminator to “Off” and ISO to “200.”

  Set Metering Mode to “Center” and White Balance to “Auto AWB.” Always use 

auto white balance (AWB) when using a strobe/flash. When recording video 

or still photos without a strobe, AWB can still be used, but for more accurate 

and consistent colors we recommend setting Custom manual white balance 

for each working depth. Custom manual white balance is also recommended 

when using a color filter and no flash.

  Set DRO/Auto HDR, Center Lock-on AF & Smile/Face Detect to “OFF.”

  Set SteadyShot to “On” and Steadyshot Adjust. to “Auto.”

-  In       CUSTOM MENU settings

Set Auto Review to “5 Sec.”

Set Eye-Start AF to “Off.” 

Set FINDER/MONITOR to “Monitor”. This option turns off eye-piece 

automation and must be set, otherwise, the camera will sense the housing 

back and shut off the LCD screen and transfer picture view to the optical 

viewfinder.

-  In        SETUP MENU settings:

Set Pwr Save Start Time to “5 min.”  

*   All other camera functions not mentioned should be set to the user’s 

preference.

Reviews: