Press and release the push button several times until the lube is
worked up into the o-ring.
Apply Ikelite
Lube Here
After completing this procedure, close the housing and submerge it in
water without the camera inside. Check the control for watertightness.
Although not recommended, if it is necessary to remove a housing
push button, DO NOT re-use the E-clip. Contact Ikelite for
replacement E-clips (part #0319.12).
In the unlikely event one of the control shafts sticks or becomes
difficult to operate, you can remove the control from the housing and
lubricate it, or return the housing to Ikelite for maintenance. Your
housing may feature both round and hex style control glands. To
remove a control in a round style gland, loosen the set screw in the
knob (hex head wrench required); remove the knob.
Knob
Housing
Control Gland
O-rings
Lubricate end of shaft
before reinserting into
gland
Tighten set screw down
against this flat area
when replacing the knob
Loosen Set Screw
(Hex Head Wrench Required)
Control
Shaft