32
71702-73702-canon-5d-markIV-1-1216
Page 1: ...rchase Our product registration database is the best way for us to contact you in the event of a product update 200DLUnderwaterHousingforCanonEOS5DMark III 5DMarkIV 5DS 5DSRDSLR Product Number 71702 5...
Page 2: ...visit ikelite com to register your product to receive information on any updates notices or recalls pertaining to your equipment IncludedintheBox Housing Main O ring 0132 61 Port O ring 0132 45 Zoom G...
Page 3: ...king controls turn the camera off and submerge the sealed housing in clean freshwater Operate the controls several times each while underwater to flush out any residue Never leave a housing in a rinse...
Page 4: ...g 11 Attaching the Base with Quick Release Handle 11 Opening the Housing 11 Inserting the Camera 12 Attaching the Hotshoe 13 Closing the Housing 14 Installing an Optional Zoom Gear not included with h...
Page 5: ...5 Storage 23 Lubricant 24 Push buttons 24 Control Shafts 25 Troubleshooting 27 Spare Parts 29 Limited Warranty 30 Service and Repairs 30 Contact Us 31...
Page 6: ...6 GettingtoKnowYourHousing IKELITE Shutter Button Lid Snap Accessory Port Hole Plug AF Drive Mode Meter White Balance Lens Release Vacuum Valve Plug...
Page 7: ...F ON Button Main Dial Power Switch ISO Speed Strobe Bulkhead and Cap Mode Dial INFO Button Erase Button Playback Button Index Magnify Reduce RATE Rating Button Creative Photo Comp Playback MENU Button...
Page 8: ...Pump DO NOT submerge the housing without the vacuum valve plug installed The housing will NOT be waterproof without the vacuum valve plug installed Vacuum Valve Vacuum Valve Plug Nut AccessoryPort Yo...
Page 9: ...ing to swell 4 Carefully screw in and tighten accessory fitting The accessory port features a 1 2 20 threaded hole Make sure your fitting is the same thread pattern DO NOT cross thread DO NOT overtigh...
Page 10: ...card 3 Set Mode Dial to M Set shutter speed to 1 60th second or 1 125th second for fast moving subjects Set aperture to F8 for general photography or F22 for macro photography close ups Adjust settin...
Page 11: ...le Using a flat head screwdriver attach the Tray and Handle to your housing with the two 1 4 nylon washers and 1 4 20 x 3 8 screws Opening the Housing 1 Push the lid snap lock forward and lift the cur...
Page 12: ...ove the housing back Inserting the Camera 1 Remove housing body cap 2 Remove any lanyard or neck strap which may be attached to the camera 3 Check to see whether the camera s lens will fit through the...
Page 13: ...the mounting plate is flush with the back of the housing mount Attaching the Hotshoe Your Ikelite housing features a factory installed Hotshoe connector which allows manual flash with Ikelite and non...
Page 14: ...using The main housing o ring does not require lubricant to make a seal 2 Place the back onto the housing front 3 Make sure no controls or wires are interfering with the o ring or the back of the hous...
Page 15: ...ontrol functions Installing an Optional Zoom Gear not included with housing 1 Lay housing on its back and remove camera lens by rotating the housing lens release control see diagram page 7 2 Remove th...
Page 16: ...so Retainer is snug DO NOT overtighten Zoom Gear Retainer Zoom Gear Port Mount 5 Attach Zoom Clamp to Lens Zoom Ring 6 Line up Zoom Clamp Slots with Zoom Gear Posts and slide lens into the housing op...
Page 17: ...into the inside of the port or extension Thumbscrew Sealing Surface Drain Hole Port Extension O ring 2 Make sure the O ring and Sealing Surface are clean and free of lint dirt or debris 3 Lightly lub...
Page 18: ...mera can obtain focus and take a photo This will not be possible when using a 4 diopter close up lens until you are underwater Adding a 4 diopter to the end of your lens is not normally necessary unle...
Page 19: ...lush away any small bubbles that may be on the face of the lens port Bubbles will produce soft focus spots in your photo or video Shooting Under Water It is important to respect all living creatures u...
Page 20: ...Sync Cords Attaching a strobe via electrical sync cord provides faster strobe recycle times as compared to a fiber optic connection and prolongs camera battery life Strobes from IKELITE SEA SEA INON a...
Page 21: ...rproof operation Never submerge the housing without either a sync cord or waterproof bulkhead cap attached 1 Remove the bulkhead cap 2 Lightly lubricate the sync cord o rings We recommend using only I...
Page 22: ...or focus assist and for improved colors when shooting video Maintenance Post Dive 1 Rinse the housing in fresh water Rotate the housing controls and press each button while submerged in fresh water to...
Page 23: ...housing be returned to Ikelite periodically to be checked and pressure tested 1 Clean the housing and controls thoroughly prior to storage 2 Remove the back and port o rings Lightly lubricate each o...
Page 24: ...sand hair or debris which may interfere with proper sealing Never use spray lubricants as the propellant ingredient can cause the plastic housing to crack or o rings to swell Push buttons To prevent...
Page 25: ...e If it is necessary to remove a housing push button never re use the e clip Push button o ring kits include replacement e clips Push buttons look similar but vary in length Remove and re install one...
Page 26: ...including the large outer end of the shaft 6 Gently re install the shaft from the inside of the housing If there is a spring associated with the control make sure it is in its proper position 7 Rotat...
Page 27: ...housing has a shutter spring DO NOT rotate the shutter control more than 1 16th of a full rotation otherwise you may accidentally bend the shutter spring or cause the spring to pop off the control sha...
Page 28: ...is properly attached Check that the hot shoe is pushed all of the way forward Buttons are stuck Soak the housing in lukewarm fresh water Depress each button several times while the housing is submerge...
Page 29: ...or snow in images Reposition strobe s or light s to light up the subject only and NOT the water in between the camera and subject Avoid using strobes in extremely low visibility conditions SpareParts...
Page 30: ...ovided to obtain warranty service No prior authorization is required You may return directly to us or through your dealer Please include a brief description of the problem any relevant email correspon...
Page 31: ...uct or need advice on getting the images you want please get in touch with us and we ll do everything we can to help you capture your unique perspective Ikelite Underwater Systems 50 W 33rd St Indiana...
Page 32: ...32 71702 73702 canon 5d markIV 1 1216...