Setting procedure for ICD-808/P, ICD-828/P, ICD-848/P (SET UP MENU)
- 8/
10
-
Adjust the COARSE by using the L and R switches.
SYNC LL
Move to FINE by using the U and D switches.
And adjust by using the L and R switches.
COARSE
0 DEG
Move to the bottom line by using the U and
FINE
L
|
•
•
•
• •
•
•
Η
D switches.
Select RET to go back to SET UP MENU or select
EXIT. And press the E switch.
RET
EXIT
Fig.22
Notes: The LL setting cannot be made in the following cases.
- DC type camera (no line lock signal input)
- NTSC system model with 50Hz power frequency or PAL system model with 60Hz
power frequency.
(3) GENLOCK
SET UP MENU
When a camera inputs external sync signal from
GENLOCK IN connector at rear panel,
CAMERA ID
OFF
SYNC item is forced to select EXT VBS or EXT VS. DAY/NIGHT
AUTO
When you select EXT VBS and press the E switch, SHUTTER
OFF
the screen of Fig.24 appears .
LIGHT CONT.
AES
GAIN
AGC
WHITE BAL.
ATW1
SYNC
EXT VBS
MENU LOCK
OFF
EXIT
CANCEL
RESET
Fig.23
Adjust the H PHASE by using the L and R
SYNC VBS
switches. Move to SC COARSE by using the U and
D switches. And adjust by using the L and R
H PHASE
L
•
•
•
• •
|
•
•
Η
switches. Move to SC FINE by using the U and D
SC COARSE
0 DEG
Switches. And adjust by using the L and R
SC FINE
L
•
•
|
•
• •
•
•
Η
switches.
RET
EXIT
Fig.24
Move to the bottom line by using the U and D switches. Select RET to go back to SET UP MENU or
select EXIT. And press the E switch.
When you select EXT VS and press the E switch,
SYNC VS
the screen of Fig.25 appears .
Adjust H PAHSE by using the L and R switches.
H PHASE
L
•
•
•
• •
|
•
•
Η
Move to the bottom line by using the U and
D switches.
Select RET to go back to SET UP MENU or select
EXIT. And press the E switch.
RET
EXIT
Fig.25