Ikegami Tsushinki Co., Ltd.
INSTRUCTION MANUAL
MODEL
ICD-68
B/W Dome Camera
OUTDOOR USE WARNING
WARNING – TO PREVENT FIRE OR
ELECTRIC SHOCK, DO NOT
EXPOSED THIS APPLIANCE TO
RAIN OR MOISTURE.
E-1.
Handling precautions
(1) Do not open the camera housing unless absolutely necessary. Otherwise, the
internal precision parts may be damaged, resulting in troubles.
(2) Do not use the camera in any place where it is exposed to water or high moisture.
Preferably use the camera at ambient temperatures of -10 to +50
°
C.
(3) While moving the camera, be careful not to drop or shock it.
(4) Do not touch the CCD faceplate.
E-2.
General
The ICD-68 is a dome-shaped black-and-white camera which employs 1/3” CCD and is
compatible with AC 24V power supply.
This lens built-in type camera which incorporates the exclusive automatically
controllable iris and variable focal lens is equipped with the basic functions such as high
sensitivity, backlight compensation, mirror imaging and line lock, for general-purpose
monitoring. Since small dome shape design is employed for the outside, it is best suited
as an indoor monitor camera that gives weight to interior decorating effect. (The unit is for
interior monitoring only.)
E-3.
Features
(1) Small dome
Since the camera and lens are encased in the small dome shell which is quite
different from the housing of ordinary camera, it is possible to monitor by image
without awareness of the location of camera. (Indoor only)
(2) Integration with variable focal lens
The unit is integrated with the focal lens variable from standard angle to x2.3 wide
angle. Imaging focal depth can be adjusted freely by removing the dome cover.
(3) High sensitivity
Employment of the high-sensitivity CCD with on-chip microlens and the high-
performance AGC signal processing provide the unit with high sensitivity of the
minimum subject illuminance as low as 0.3 lux at F1.6 (at full wide).
(4) Line lock
Since the operation of the unit is synchronized with the power supply frequency, a
stable monitor image can be obtained without generation of screen scrolling at the
time of switching of camera in automatic sequential image switching operation when
plural sets of camera are used in the monitor system.
(5) Backlight compensation
Backlight can be compensated effectively according to the intensity of subject backlight.
(6) Mirror image function
Since the unit is equipped with the mirror image function that can horizontally invert
the image by switch operation, the image obtained by indirect monitoring with use of
mirror can be flipped back to the normal image.
E-4.
Setting of Camera
①
Lens direction adjusting screw (Vertical direction)
Loosen this screw for adjusting the vertical direction of screen.
②
Lens direction adjusting screw (Horizontal direction)
Loosen this screw for adjusting the horizontal direction of screen.
③
Iris level control (IRIS LEVEL)
This control is for adjusting the lens aperture. The screen light level can be adjusted
freely to be easy to see.
④
Line lock phase control (LL PHASE)
This control is for adjusting the line lock phase.
⑤
Backlight compensation level control (BLC LEVEL)
This control is for adjusting the effect of backlight compensation when the backlight
selector switch is turned ON.
⑥
Backlight compensation selector switch (BLC)
This switch is for selecting ON/OFF of the backlight compensating function.
⑦
Mirror image selector switch (MIR)
This switch is for selecting either of the normal image and the mirror image.
⑧
Test monitor image output terminal (MON. OUT)
Positioning and focus adjustment can be made easily by connecting this terminal to
the VIDEO IN or the video input terminal of the monitor when setting the camera.
(Connect to 75
Ω
terminal.)
⑨
Dome cover
⑩
Lower case
⑪
Upper case
⑫
AC 24V power supply input cable
Input the power supply of AC 24V
±
10%.
※
This installation should be made by a qualified service person and should
conform to all local codes.
⑬
Video output cable
This is the cable with video signal output terminal, which is connected to the video
input terminal of the monitor or the switcher. (Connect to 75
Ω
terminal.)
Ikegami Electronics (U.S.A.), Inc.
37 Brook Avenue, Maywood, New Jersey 07607, U.S.A.
Phone: (201) 368-9171, FAX 201-569-1626
Ikegami Electronics (Europe) GmbH
Ikegami Strasse 1, 41460 Neuss 1, F.R. Germany
TEL. 02131-123-0/FAX 02131-102820
Ikegami Electronics (Europe) GmbH U.K. Branch
Unit E1 Cologne Court Brooklands Close, Windmill Road Sunbury-
on-Thames Middlesex TW16 7EB, UK
TEL. 01932-769700/FAX 01-92-769710
K32775
English
E-6.
Connection
6-1. Cable with power supply input and video output terminals
• This cable is the video/power composite cable.
• Connect the power supply cable to the AC 24V
±
10% power supply.
• The cable with BNC connector is the video output terminal. Connect it to the VIDEO
IN or video input terminal of the monitor or the switcher. (Connect to 75
Ω
terminal.)
• Use a coaxial cable for video output.
E-5.
Names of parts and their functions
A
A'
B
Distribution
hole
ø50 - ø60
Mounting dimensions
M4 mounting screw position PCD93
Mounting
metal
△
mark
M4 mounting
screws (4 pos.)
Setscrew
(Camera
body
inside)
Camera
front side
Camera body
Dome cover
Insert a screwdriver and turn the
setscrew clockwise to fix the camera.
Step 1
Drill a distribution hole (approx. 50 mm -
60 mm dia.) and prepared holes for M4
mounting screws. However, it is not
necessary to drill the distribution hole
when leading out the cables from the
side of the camera body.
Step 2
Remove the dome cover from the
camera body according to the procedure
of “How to Remove the Dome Cover”.
Step 3
Fix the attached mounting metal with M4
screws. The
△
mark stamped on the
mounting metal indicates the camera
front side that should come to the front
when mounting camera.
Step 4
Fit the portions “A” of the mounting metal
into the holes A’ (2 pos.) and turn the
camera body fully counterclockwise.
When leading out the cables from the
side of the camera and connecting them,
draw out the cables through the notch
“B”.
Step 5
Tighten the setscrew provided inside the
camera body with screwdriver and fix the
camera to the mounting metal.
Step 6
After the completion of lens adjustment
and user setting-up, mount the dome
cover according to the procedure of
“How to Mount the Dome Cover”.
CAUTION
After setting the camera, turn the dome cover
clockwise and make sure that it has been
mounted securely.
The exclamation point within an equilateral triangle is intended to alert
the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanying the appliance.
NOTE:
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user
will be required to correct the interference at his own expense.
CAUTION;
ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY
APPROVED BY THE PART RESPONSIBLE FOR COMPLIANCE COULD
VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT.
NOTA:
Este equipo ha sido probado y ha demostrado cumplir con los límites
establecidos para los dispositivos digitales de la clase A, en conformidad con
el Apartado 15 de los Reglamentos de la FCC. Estos límites han sido
diseñados para proporcionar una protección razonable contra la
interferencia perjudicial si el equipo se utiliza en un entorno comercial. Este
equipo genera, utiliza y puede radiar energía radioeléctrica, y, si no se
instala y usa de acuerdo con las instrucciones, puede causar interferencias
perjudiciales en las comunicaciones por radio, en conformidad con el
Apartado 15 de los Reglamentos de la FCC. Estos límites han sido
establecidos para proporcionar una protección razonable, el usuario tendrá
que corregir la interferencia corriendo él a cargo de los gastos pertinentes.
PRECAUCIÓN;
CUALQUIER CAMBIO O MODIFICACIÓN QUE NO HAYA
SIDO APROBADO EXPRESAMENTE POR LA PARTE RESPONSABLE
PODRÍA ANULAR LA AUTORIZACIÓN QUE TIENE EL USUARIO PARA
UTILIZAR EL EQUIPO.
El signo de exclamación en el interior de un triángulo equilátero tiene la
finalidad de avisar al usuario de la presencia de instrucciones de utilización y
mantenimiento (servicio) importantes en el manual que acompaña al aparato.
Thank you very much for your wise choice of the Ikegami B/W Dome
Camera. Please carefully read this Instruction Manual to keep your camera
at full capacity.
Muchísimas gracias por haber elegido la Cámara en blanco y negro con forma
de cúpula de Ikegami. Lea cuidadosamente este manual de instrucciones
para mantener su cámara en las mejores condiciones de funcionamiento.
6-2. Test monitor video output terminal (MON. OUT)
• This terminal is the video output terminal (pin jack).
• Positioning and focus adjustment can be made easily by connecting this terminal to
the VIDEO IN or the video input terminal of the monitor when setting the camera.
E-7.
Lens Adjustment
Adjustment of variable focus lens
Remove the dome cover before lens adjustment.
①
Dome cover
Catch A
●
Adjustment of field angle and focus
(1) Turn the zoom lever (WIDE
⇔
TELE) near the camera and set the field angle
as desired.
(2) Next, adjust the focus by turning the focus lever (FAR
⇔
NEAR).
(3) If desired imaging field can not be obtained, repeat the steps (1) and (2).
(4) When the adjustment is over, tighten the treaded portions of the zoom lever
and focus lever to fix the levers.
The zoom lever and focus lever have threaded
portions. Adjust the levers after the threaded
portions are loosened and tighten the threaded
portions to fix the levers after adjustment.
Catch D
Catch C
Catch B
②
Dome cover
1.
Turn the dome cover in the
direction 1 (counterclockwise).
2.
The dome cover can be removed
by holding up the catches A and
B while pressing around the
catches B and D (or A and C) of
the dome cover.
Focus lever
Zoom lever
●
How to Mount the Dome Cover
②
Dome cover
1.
Fit and press the catches (4 pos.)
of the dome cover into the
mounting holes
①
of the camera
body and mount the dome cover.
2.
Turn the dome cover in the
direction
②
(clockwise) and fix it.
CAUTION
After the completion of dome cover
mounting, make sure that the
catches have been completely
moved up to the catch fixing
positions.
Mounting
hole
①
①
①
①
Mounting
hole
Mounting
hole
Mounting
hole
Catch fixing
position
11
10
5
9
4
8
1
2
3
6
7
12
13
ICD-68
VCR
MONITOR
POWER
E-8.
Warranty and after-sale service
A warranty accompanies this product. Read and fill out the warranty card that you
have received at your dealer. Keep this card in a safe place.
· Please consult Ikegami Electronics (U.S.A.) Inc. or your dealer for full warranty
information. Your dealer will repair or replace free of charge within the warranty
period according to the warranty coverage.
· For repairs after the expiration of the warranty period, consult your dealer or
sales representative. It will first be judged whether the trouble is repairable or
not. Charged servicing will then be made upon request of the user.
· Before you ask for servicing, take trouble of reading the Instruction Manual. If
the unit still fails, take note of the model number, date of purchase, problem, etc.
in detail, and inform your dealer or sales representative.
· If you have questions about the after-sale service, contact your dealer or sales
representative.
※
We suggest you ask for preventive inspection earlier.
E-9.
Specifications
(1)
Imaging device:
1/3 inch, interline transfer type CCD
No. of effective pixels:
512 (H) x 492 (V) lines, approx. 250,000 pixels
(2)
Sensing area:
4.8 (H) x 3.6 (V) mm
(3)
Scan system:
EIA, 2:1 interlace
(4)
Sync system:
Line lock (phase adjustable)
(5)
Vertical sync frequency:
60Hz
(6)
Horizontal sync frequency:
15.75kHz
(7)
Video output:
①
VIDEO OUTPUT:
VS1. 0Vp-p/75
Ω
②
MON. OUTPUT:
VS1. 0Vp-p/75
Ω
(8)
Horizontal resolution:
380 TV lines
(9)
S/N ratio:
48 dB (at standard illuminance, weight-ON)
(10) Subject illuminance
• Rated illuminance:Approx. 300 lux
(tungsten light source, at
• Range of illuminance for actual use:
89.9% subject reflectance):
Approx. 0.3 - 100,000 lux
●
How to Remove the Dome Cover
②
(Typical connections)