EnGLiSH
11
Type of gas used
Type of
burner
injector
marking
Rated
thermal
flow rate
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure
(mbar)
min. rat. max.
NATURAL GAS
(Methane)
G20
rapid
semi-rapid
auxiliary
118 F2
101 Z
72 X
3,00
2,00
1,00
286 l/h
190 l/h
95 l/h
0,60
0,35
0,30
17
20
25
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
(Propane)
G31
rapid
semi-rapid
auxiliary
85
69
50
3,00
2,00
1,00
218 g/h
145 g/h
73 g/h
0,60
0,35
0,30
25
37
45
injector table
Category ii2H3B/P
Type of gas
used
Model
configuration
4 BURnERS
Rated thermal
flowrate (kW)
Total rated
consumption
Air required (m
3
)
for burning1m
3
of gas
G20
20 mbar
1 R - 2 SR
1 AUX
8,00
761 l/h
9,52
G30/G31
30 mbar
1 R - 2 SR
1 AUX
8,00
581 g/h
30,94
Electric Power: 220 - 240 V ~ 50/60 Hz