Problem
Possible cause
Remedy
The flame is blowing out im-
mediately after lightning
Thermocouple is not heated
enough
After lightning the flame,
keep the knob pushed for
about 5 sec.
The gas ring burns unevenly Burner crown is blocked with
food residues
Check the main injector is
not blocked and the burner
crown is clear of food parti-
cles.
If there is a fault, first try to find a solution to
the problem yourself. If you cannot find a
solution to the problem yourself, contact the
After Sales Service (refer to the Service
chapter).
If you operated the appliance wrongly,
or the installation was not carried out
by a registered engineer, the visit from the
customer service technician or dealer may
not take place free of charge, even during
the warranty period.
Technical data
Hob dimensions
width
744 mm
depth
510 mm
built in height
30 mm
Class Appliance: 3
Appliance Category: II2L3B/P
Appliance gas supply: G25 (2L) 25 mbar
This appliance is designed for use with nat-
ural gas but can be converted for use with
other gas type according to table below.
Type of Gas
Burner
type
Injectors
1/100
mm
Nominal
Power
kW
Nominal
Flow g/h
Reduced
Power kW
by-pass
1/100 mm
G25 (2L) 25
mbar
Ultra-
rapid
(large)
147
4.0
-
1.4
56
Rapid
124
3.0
-
0.75
42
Semi-
rapid
100
2.0
-
0.45
32
Auxiliary
(small)
071
1.0
-
0.33
28
G30/G31
(3B/P)
30/30 mbar
Ultra-
rapid
(large)
98
4.0
291
1.4
56
Rapid
86
2.8
204
0.75
42
Semi-
rapid
71
2.0
145
0.45
32
ENGLISH
9
Summary of Contents for FRAMTID HGA5K
Page 1: ...FRAMTID HGA5K GB NL NL...
Page 2: ......
Page 3: ...NL ENGLISH 4 NEDERLANDS 16 Language Taal Country Land...
Page 30: ...30...
Page 31: ...31...
Page 32: ...Inter IKEA Systems B V 2008 AA 508307 2 397172501 D 132011...