4
The maximum mixed water temperature can be 2°C above the recommended maximum set
mixed water temperature.
The mixed water temperature must never exceed 46°C.
46°C is the maximum mixed water temperature from the bath tap and takes account of
allowable temperature tolerances inherent in thermostatic mixing valves and temperature
losses in metal baths. It is not a safe bathing temperature for adults or children.
37°C is the maximum recommended temperature for children/babies under 18 months,
40°C is the maximum recommended temperature for adults/children over 18 months.
UK installations only - For Type 2 approved valves, additional installation, commissioning
and in-service test requirements shall be followed. Refer to the Type 2 approved valves
document available at www.IKEA.com.
Application
Bath:
Shower:
Bath/Shower:
Maximum outlet temperature
44 °C / 111 ˚F
41 °C / 106 ˚F
41 °C / 106 ˚F
Recommended maximum set mixed water temperatures
1. Valves operating outside these conditions of use cannot be guaranteed to operate as Type
2 valves (intended operation not guaranteed).
2. If water supply is fed from a storage cistern by gravity then the supply pressure should be
verified to ensure the conditions of use are appropriate for the valve.
3. Hot and cold supply pressure should be balanced.
4. The thermostatic mixer is pre-set to a safety stop temperature of 38 °C. Since operating
conditions in each supply system varies, it might be necessary to calibrate the mixer
according to the service and installation instructions.
5. You can override the safety stop temperature by pressing the override button.
Designation of use:
Maximum static pressure:
Minimum working pressure:
Maximum working pressure
Recommended working pressure (hot & cold):
Max hot water temperature:
Recommended hot water temperature:
Recommended cold water temperature:
Flow rate (bath):
HP (high pressure supply system)
10 bar (145 PSI)
0.5 bar (7.25 PSI)
10 bar (145 PSI)
1 – 5 bar (14.5 - 72.5 PSI)
80 ˚C / 176 ˚F
60 - 65 ˚C / 140 - 149 ˚F
10 - 15 ˚C/ 50 - 59 ˚F
20 l/min (5 gpm) @ 3 bar (43.5 PSI)
OPERATING CONDITIONS
ENGLISH