Oven Installed in Cabinet

Cabinet Side View

Electrical Requirements

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.
It is not recommended to ground to a gas pipe.
Check with a qualified electrical installer if you are not sure the 
oven is properly grounded.

It is not recommended to have a fuse in the neutral or ground 
circuit.
This oven must be connected to a grounded metal, permanent 
wiring system.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition or CSA Standards C22.1-94, Canadian Electrical 
Code, Part 1 and C22.2 No. O-M91-latest edition, and all local 
codes and ordinances.

A copy of the above code standards can be obtained from:

 National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

Electrical Connection

To properly install your oven, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.

Oven must be connected to the proper electrical voltage and 
frequency as specified on the model/serial number rating 
plate. The model/serial number rating plate is located at the 
bottom of the right-hand mounting rail. See the following 
illustration.

Models rated at 7.2 kW and below at 240 volts (5.4 kW and 
below at 208 volts) require a separate 30-amp circuit.

A time-delay fuse or circuit breaker is recommended.

Connect directly to the fused disconnect (or circuit breaker 
box) through flexible, armored or nonmetallic sheathed, 
copper cable (with grounding wire). See “Make Electrical 
Connection” section. 

Flexible cable from oven should be connected directly to the 
junction box.

Fuse both sides of the line.

Do not cut the conduit. The length of conduit provided is for 
serviceability of the oven.

A UL listed or CSA approved conduit connector must be 
provided.

If the house has aluminum wiring, follow the procedure below:

1.

Connect a section of solid copper wire to the pigtail 
leads.

2.

Connect the aluminum wiring to the added section of 
copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.

A.

24

" (61.0 cm) min. cabinet width

B. 1" (2.5 cm) top of cutout to bottom of upper 

cabinet door

C. 32" (81.3 cm) bottom of cutout to floor
D . 22

¹⁄₂

" (57.2 cm) cutout width

E. 1

¹⁄₂

" (3.8 cm) min. bottom of cutout to top of 

cabinet door

F. 23

¹⁄₃₂

" (58.5 cm) min. cutout height

A. 23

¹⁄₄

" (59.1 cm) min. cutout depth

B. 23" (58.4 cm) recessed oven depth
C. Oven front
D. Recessed oven

E. Cabinet

A

B

C

D

E

F

A

B

C

D

E

Single Oven

A. Model/serial number plate

A

Summary of Contents for 24 inch

Page 1: ...installation 12 IMPORTANT Save for local electrical inspector s use IMPORTANT À conserver pour consultation par l inspecteur local des installations électriques 501910200218 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of inj...

Page 2: ...d 3 7 6 cm maximum below the support surface when the oven is installed in a wall cabinet A 1 2 5 cm minimum diameter hole should be located in the right rear or left rear corner of the support surface to pass the appliance cable through to the junction box NOTE For undercounter installation it is recommended that the junction box be located in the adjacent right or left cabinet If you are install...

Page 3: ... plate is located at the bottom of the right hand mounting rail See the following illustration Models rated at 7 2 kW and below at 240 volts 5 4 kW and below at 208 volts require a separate 30 amp circuit A time delay fuse or circuit breaker is recommended Connect directly to the fused disconnect or circuit breaker box through flexible armored or nonmetallic sheathed copper cable with grounding wi...

Page 4: ...is oven is manufactured with a neutral white power supply wire and a cabinet connected green or bare ground wire twisted together 1 Disconnect power 2 Feed the flexible cable conduit from the oven through the opening in the cabinet 3 Remove junction box cover if it is present 4 Install a UL listed or CSA approved conduit connector to the junction box 5 Route the flexible cable conduit from the ove...

Page 5: ...er using a UL listed wire connector 2 Connect the 2 white wires D and the green or bare ground wire of the oven cable using a UL listed wire connector 3 Connect the 2 red wires G together using a UL listed wire connector 4 Install junction box cover Install Oven 1 Attach and securely fasten one mounting rail to each side of the cabinet using two 4 x 13 mm screws Do not overtighten screws 2 Using t...

Page 6: ...l light briefly and PF should appear in the display 16 If display panel does not light please reference the Assistance or Service section of the Use and Care Guide or contact the dealer from whom you purchased your oven Complete Installation 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your t...

Page 7: ...ssous de la surface de support lorsque le four est installé dans un placard mural Percer un trou de diamètre 1 2 5 cm ou plus dans l angle arrière gauche ou droit de la surface de support pour le passage du câble d alimentation jusqu au boîtier de connexion REMARQUE Pour l installation sous un plan de travail on recommande que le boîtier de connexion soit situé dans le placard adjacent à droite ou...

Page 8: ...uant à la qualité de la liaison à la terre du four consulter un électricien qualifié Il n est pas recommandé d installer un fusible dans le conducteur neutre ou le conducteur de liaison à la terre A Largeur encastrement 21 54 5 cm max B Hauteur encastrement 22 57 2 cm C Hauteur hors tout 23 59 5 cm max D Profondeur encastrement 21 53 8 cm max E Largeur hors tout 23 59 5 cm A Largeur placard 24 61 ...

Page 9: ... est équipé d un câblage en aluminium suivre les instructions suivantes 1 Connecter une section de câble en cuivre massif aux conducteurs en queue de cochon 2 Connecter le câblage en aluminium à la section ajoutée de câblage en cuivre en utilisant des connecteurs et ou des outils spécialement conçus et homologués UL pour fixer le cuivre à l aluminium Appliquer la procédure recommandée par le fabri...

Page 10: ...ctions et au Canada 1 Connecter ensemble les 2 conducteurs noirs B avec un connecteur de fils homologation UL 2 Connecter ensemble les 2 conducteurs rouges C avec un connecteur de fils homologation UL 3 Détorsader le conducteur blanc du conducteur vert ou nu de liaison à la terre provenant du four 4 Connecter ensemble les 2 conducteurs blancs F avec un connecteur de fils homologation UL 5 Connecte...

Page 11: ...nt chaque rail de montage de chaque côté du placard à l aide de deux vis de 4 x 13 mm Ne pas serrer excessivement les vis 2 À l aide de deux personnes ou plus soulever le four par les poignées latérales situées de chaque côté du four Insérer délicatement le four dans l ouverture du placard 3 Pousser contre la zone du joint du châssis avant pour introduire le four dans le placard A Câble depuis le ...

Page 12: ... affichage ne s allume pas consulter la section Assistance ou service du Guide d utilisation et d entretien ou contacter le marchand qui vous a vendu le four Achever l installation 1 Vérifier que toutes les pièces sont maintenant installées S il reste une pièce passer en revue les différentes étapes pour découvrir laquelle aurait été oubliée 2 Vérifier la présence de tous les outils 3 Jeter recycl...

Reviews: