www.ikancorp.com | 1.713.272.8822 | [email protected]
because we’re
filmmakers
too
Periodic Fixture Inspection
1. The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 working hours or at least once a year. This
frequency may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar
spare parts.
2. The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged, otherwise
explosion might occur. Defer to instructions provided by the lamp manufacturer.
3. Always check the safety shield before every use.
4. All high-voltage components (ex: voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a
year.
5. Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety shield. This will allow
inspections of accessories and the holding clamps.
6. The condition of the internal mirror must be maintained every 250 working hours. It must be replaced whenever it becomes either cracked or
broken. It is essential for the performance of the fixture.
Specifications & Photometrics
LSC-001 Specifications
Beam Angle
9° to 50°
Build Material
Aluminum
Color Temperature
5600K
Cooling System
Air Cooled
Fixture Size
12.8 x 8.9 x 7.7 in.
Fixture Weight
9 lbs
Focusing
Knob Control
Head Type
HMI Fresnel 200W
IP Class
IP23
Lamp Base
200W / 70V / GZY9.5
Lens Size
Fresnel 4.4"
Yoke
Cast Aluminum with 1 1/8" Pin
LUX
METERS
1.5M
2M
3M
3.5M
4M
2.5M
16875
7500
4220
LUX
METERS
1.5M
2M
3M
3.5M
4M
2.5M
2520
1120
630
FC
FEET
2'
4'
6'
8'
10'
12'
14'
1567.7
696.8
392.1
FC
FEET
2'
4'
6'
8'
10'
12'
14'
234.1
104
58.5