Periodic Fixture Inspection

1.  The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 working hours or at least once a year. This 

frequency may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar 
spare parts. 

2.  The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged, otherwise 

explosion might occur. Defer to instructions provided by the lamp manufacturer.  

3.  Always check the safety shield before every use. 

4.  All high-voltage components (ex: voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a 

year. 

5.  Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety shield. This will allow 

inspections of accessories and the holding clamps. 

6.  The condition of the internal mirror must be maintained every 250 working hours. It must be replaced whenever it becomes either cracked or 

broken. It is essential for the performance of the fixture.

Specifications & Photometrics

LSC-001 Specifications

Beam Angle

9° to 50°

Build Material

Aluminum

Color Temperature

5600K

Cooling System

Air Cooled

Fixture Size

12.8 x 8.9 x 7.7 in.

Fixture Weight

9 lbs

Focusing

Knob Control

Head Type

HMI Fresnel 200W

IP Class

IP23

Lamp Base

200W / 70V / GZY9.5

Lens Size

Fresnel 4.4"

Yoke

Cast Aluminum with 1 1/8" Pin

LUX

METERS

1.5M

2M

3M

3.5M

4M

2.5M

16875

7500

4220

LUX

METERS

1.5M

2M

3M

3.5M

4M

2.5M

2520

1120

630

FC

FEET

2'

4'

6'

8'

10'

12'

14'

1567.7

696.8

392.1

FC

FEET

2'

4'

6'

8'

10'

12'

14'

234.1

104

58.5

Summary of Contents for LSC-001

Page 1: ...01 Quick Start Guide 200 Watt HMI Fresnel Head Lightstar What s Included 1 x 200 Watt Fixture Head 1 x Yoke 1 x Barn Doors 1 x Gel Holder www ikancorp com 1 713 272 8822 sales ikancorp com because we re filmmakers too ...

Page 2: ...e fixture in place WARNING DO NOT USE THE LSC 001 IN A SPACE WITH FLAMMABLE SUBSTANCES WARNING UV RISK HEALTH RISK THE LAMPS USED WITH THE LSC 001 EMIT AN AMOUNT OF UV RADIATION WHICH CAN BE DANGEROUS TO HUMAN HEALTH IF NOT PROPERLY SHIELDED AGAINST THE FIXTURE MUST NEVER BE USED IN SITUATIONS WHEN DIRECT LIGHT EMISSIONS FROM THE LAMP CAN OCCUR Ex No front glass no intentional mirror damaged front...

Page 3: ...ed every 100 working hours or at least once a year 5 Outer door hinges and latching system must be checked every 250 working hours to ensure proper seating of the safety shield This will allow inspections of accessories and the holding clamps 6 The condition of the internal mirror must be maintained every 250 working hours It must be replaced whenever it becomes either cracked or broken It is esse...

Page 4: ... service fee will be charged if the warranty period is expired Free Service will not be Provided in the Following Situations Even if the product is still within the warranty period Damage caused by abuse or misuse dismantling or changes to the product not made by the company Damage caused by natural disaster abnormal voltage and environmental factors etc 2017 ikan Corporation All rights reserved w...

Reviews: