background image

www.ikancorp.com | 1.713.272.8822 | [email protected] 

because we’re 

filmmakers

 too

Ballast Installation Instructions

Connecting a fixture to the ballast and energizing the ballast with power.

Make sure the ballast and the lamp head fixture is compatible.
Check that the ballast is appropriate for the AC Power that will energize the ballast and fixture. (Voltage & Frequency)
The ballast needs to be properly grounded and the main power switch is in the OFF position.
The lamp with proper wattage is fitted into the head fixture.
Make sure the AC Power is not higher than the max power of the ballast.
The safety glass shield is in good working order with no cracks or anomalies. The safety glass is in the proper position and there is a safety wire guard.

Periodic Fixture Inspection

•  The condition of the internal wiring and ceramic base will need to be inspected and tested every 4000 working hours or at least once a year. This 

frequency may need to be increased if the fixture has endured rough treatment. All internal components should only be replaced with Lightstar 
spare parts.

•  The lamps should be checked every 100 working hours. The lamp should be changed if the lamp becomes deformed or damaged, otherwise 

explosion might occur. Defer to instructions provided by the lamp manufacturer.

•  Always check the safety shield before every use.
•  All high-voltage components (Ex: Voltage wires, lamp ceramic, external shield, igniter must be inspected every 100 working hours or at least once a 

year.

•  Outer door hinges and latching system must be checked every 250 working hours. It must be replaced whenever it becomes either cracked or 

broken. It is essential for the performance of the fixture.

Specifications

Fixture Specifications

Head Type

HMI Fresnel 6000W

Lens Type

Fresnel 16.5" Lens

Lamp Base

6000W/200V/G38

Beam Angle

6° - 58°

Control/Dimming

50%-100%

Focusing

Knob Control

Build Material

Aluminum

Cooling System

Air Cooled

Yoke

Cast Aluminum w/ 1 1/8

"

 pin

IP Class

IP23

Fixture Size

36.6 x 27.5 x 24.2 in.

Fixture Weight

85 lbs

Electronic Ballast Specifications

Power Supply

Electronic Ballast 6000W

Input Voltage

180-250VAC

Electronic Ballast Size

14.2 x 10.2 x 17.7 in.

Electronic Ballast 

Weight

50.7 lbs

Shipping Specifications

Shipping Dimensions Box 1

30 x 25 x 28 in.

Shipping Dimensions Box 2

24 x 15 x 25 in.

Shipping Weight

144 lbs

Reviews: