Getting to know your LIGHTSTAR Light

The Lightstar LSW-010 (150 Watt) LSW-001 (300 Watt) LSW-002 (650 Watt) fixtures are intended for professional applications, and are only to be operated 
by qualified persons. Please read the following operating instructions very carefully before using these fixtures. They contain important information on the 
operation of Lightstar lighting. 

For your own safety, please follow all safety instructions and warnings. Please follow the operating instructions of the lamp manufacturers. Please keep 
these operating instructions for you and subsequent users to reference in the future.

CAUTION: These fixtures use high voltage, before replacing the lamp; disconnect the fixture from its power supply. Warning! Lamp 
may be hot! Allow the lamp to cool down sufficiently before replacing it. Do not switch on the Fixture without a lamp inserted. Do not 
switch on the fixture without a Fresnel lens, safety mesh and reflector in place.  Warning! The housing of the fixture can achieve very 
high temperatures. Do not cover any ventilation slots. Always keep the mains cables away from the hot housing. A risk of overheating 
or fire can occur if misused. Do not overtax the fixture cables for transport or suspension of fixture. Always remove the lamp from the 
fixture for transport. Do not operate the fixture if it shows any visible damage.

Mounting the Fixture

Loosen the thumb screw on the yoke. Bring the fixture to the desired position. Tighten thumb screws until it locks in place. Check to ensure the fixture is 
securely fastened.

If the fixture is being used in a hanging position, be sure to secure the fixture with a safety cable from the mounting pipe or truss. Accessories, not secured 
with a safety rope must be secured with a safety cable as well. The carrying capacity of the safety rope must be rated at a minimum of 10 times the 
weight of the fixture system including accessories. Stands must be set up in a stable position and capable of carrying the weight of the fixture including 
accessories and cables.

Getting the Fixture Operational

Inserting the Lamp

Before replacing the lamp, the fixture must be disconnected from the power supply. Before inserting, visually check the lamp for functionality. Damaged 
lamps must not be operated. Ensure the lamp is firmly fastened in its socket and the lamp must match the fixtures voltage. Connect the lamp head 
connector to the power source, and put the cable switch to the ON position.

For the LSW-010 (150 Watt) fixture, loosen the small black screw at the rear of the fixture and pull out the carriage which accommodates the lamp holder 
and reflector. Pull out the lamp carefully into the lamp holder. Push the lamp carriage back and fasten the small black head screw.

For the LSW-001 (300 Watt) and LSW-002 (650 Watt) press gently against the top cover to open the cover lock and lift the cover. Turn the focus knob 
to move the lamp carefully with a cloth or glove. WARNING! The contact pins of the lamps have different diameters and have to be matched to the right 
contact point of the lamp holder. Insert the lamp carefully as far as possible into the lamp holder. Close the top cover and gently press it down until you 
hear it lock in the cover lock.

Ikan is the exclusive distributor of Lightstar products in the United States.

Summary of Contents for Lightstar LSKT-001

Page 1: ...e we re filmmakers too What s Included 1 x 150W Tungsten Fresnel 1 x 300W Tungsten Fresnel 1 x 650W Tungsten Fresnel 1 x Scrim Set for 150W 1 x Scrim Set for 300W 1 x Scrim Set for 650W 1 x Gel Frame...

Page 2: ...ensure the fixture is securely fastened If the fixture is being used in a hanging position be sure to secure the fixture with a safety cable from the mounting pipe or truss Accessories not secured wit...

Page 3: ...ccessories Some other products that work well include ROLLR STND10 SW 04 KCP 703 2 Stage Roller Stand 10ft 6 in Safety Wire Stage Clamp with 16mm Stud LSKT Kit Specs Shipping Dimensions 36 x 16 x 16 i...

Page 4: ...Beam Diameter 2 4m 3 4m 4 4m LSW 010 Specs Head Type 3200K Rating AC Volts 120 v ac 50 60Hrz Light Source 1 150 Watt Bulb Power Supply 6 ft Power Cable Dimming N A Control Focusing Knob Lens 1 9 In F...

Page 5: ...Beam Diameter 1m 2 0m 3 0m LSW 001 Specs Head Type 3200K Rating AC Volts 120V AC 50 60Hrz Light Source 1 300 Watt Bulb Power Supply 6 ft Power Cable Dimming N A Control Focusing Knob Lens 3 1 In Fres...

Page 6: ...Beam Diameter 2 4m 3 4m 4 4m LSW 002 Specs Head Type 3200K Rating AC Volts 120 v ac 50 60Hrz Light Source 1 650 Watt Bulb Power Supply 6ft Power Cable Dimming N A Control Focusing Knob Lens 4 4 In Fr...

Page 7: ...service fee will be charged if the warranty period is expired Free Service will not be Provided in the Following Situations Even if the product is still within the warranty period Damage caused by abu...