IKA 20015936 Operating Instructions Manual Download Page 9

 
 

 

9

 

  Lieferumfang / Content of delivery 

 
 
 
 
 

 

Menge / 
Quantity 

Mat.-Nr. / 
Mat. no. 

Bezeichnung /  
Description 

Geteilt 

divided 

Ungeteilt 

undivided 

40001849 

Geteilte Zellen  

Divided Cells 

 

40001859 

Ungeteilte Zellen  

Single Cells 

 

40001854 

Aluminium Block 
6 Zellen 

Aluminum block  
6 cells 

 

40001855 

Aluminium Block  
8 Zellen 

Aluminum block  
8 cells 

 

12/8 

40001845 

Kronenrüher 

Crown stirrer 

40003663 

Kabelset mit 
Krokodilklemmen 
(Kanäle 1-4) 

Set of cables with 
crocodile clamps 
(Channel 1-4) 

 3887700 

Winkelschrauben-
dreher 

Allen wrench  

20018590 

Kabelset mit 
Krokodilklemmen 
(Kanäle 5-8) 

Set of cables with 
crocodile clamps 
(Channel 1-4) 

12/16 

20003456 

Graphit Elektroden 

Graphite Electrodes 

25004601* 

RCT Digital 

RCT Digital 

40003604  

Netzgerät 

Power Supply 

40004041  
Nur Japan-
Variante 

Spannungswandler 
100V zu 230V 

Step-up transformer 

1545100 

Stativstab H16V 

Support rod H16V 

3547700 

Haltestange H38 

Holding rod H38 

2437700 

Kreuzmuffe H44 

Cross sleeve H44 

40004123 

BA Screening system 

OMI Screening 
system 

*Ländervarianten beachten / observe country specific variants 

 
Weiteres Zubehör finden Sie unter: 

www.ika.com

See more accessories on

 

www.ika.com

 

 

Summary of Contents for 20015936

Page 1: ...Screening system DE Betriebsanleitung EN Operating instructions Weitere Sprachen finden Sie unter www ika com For further languages visit www ika com...

Page 2: ...ontents Sicherheit 3 Safety 6 Lieferumfang Scope of delivery 9 Montage Assembly 11 Bedienung Operation 13 Fehlerbehebung Fault rectification 14 Reinigung und Wartung Cleaning and maintenance 15 Techni...

Page 3: ...st Der Ger tschutz kann besch digt sein Bei Unsicherheit ob das Netzger t richtig funktioniert von einer Fachwerkstatt reparieren lassen Buchsen Funktionen und Bereiche bestimmungsgem f r das jeweilig...

Page 4: ...einer ebenen stabilen sauberen rutschfesten trockenen und feuerfesten Fl che aufstellen Sicherstellen dass vor dem Ger teaufbau 1 m freie Fl che besteht Sicherstellen dass Sicherungshalter nicht berb...

Page 5: ...ebung Kapitel Reinigung Wartung Kapitel Technische Daten Positionsnummer Zeigt f r Handlungen relevante Ger tekomponenten an Richtig Resultat Zeigt die korrekte Durchf hrung bzw das Resultat eines Han...

Page 6: ...the power supply unit Do not use the power supply unit if it is not working correctly The device guard may be damaged If you are unsure whether the power supply unit is working correctly have it repai...

Page 7: ...GLP guidelines Good Laboratory Practice Repairs must only be carried out by a qualified technician who is aware of the possible dangers Place devices on an even stable clean non slip dry fire resistan...

Page 8: ...lt rectification chapter Cleaning and maintenance chapter Technical data chapter Item numbers Indicates relevant device components for actions Correct result Indicates correct implementation or the re...

Page 9: ...elschrauben dreher Allen wrench x x 1 20018590 Kabelset mit Krokodilklemmen Kan le 5 8 Set of cables with crocodile clamps Channel 1 4 x x 12 16 20003456 Graphit Elektroden Graphite Electrodes x x 1 2...

Page 10: ...nium Block 6 Zellen Aluminum block 6 cells Aluminium Block 8 Zellen Aluminum block 8 cells Kronenr her Crown stirrer Elektroden elelctrodes RCT Digital Netzger t Power supply Stativstab H 16V Support...

Page 11: ...eihe rot rot Channel 1 Reaktionskammer 1 Channel 2 Reaktionskammer 2 Etc 7 RCT Temperatur und Drehzahl einstellen 8 Fernsteuerung ber labworldsoft serielle Kabel an RCT Netzteil bzw ber USB 1 Setting...

Page 12: ...darf nicht ber den durch ein gestricheltes Rechteck gekennzeichneten sicheren Bereich hinausragen Risk of tipping Make sure that the center of mass of the attached device does not protrude over the sa...

Page 13: ...Bedienung Operation Siehe Betriebsanleitungen f r Magnetr hrer RCT Digital Rohde Schwarz HMP4040 Netzteile Operating instructions for Magnetic Stirrer RCT Digital Rohde Schwarz HMP4040 power supply un...

Page 14: ...zierungen durchf hren Sicherstellen dass das AC Stromkabel an das Netzteil angeschlossen ist Sicherstellen dass der Netzschalter an der Frontblende niedergedr ckt ist Sicherstellen dass die korrekte N...

Page 15: ...gs oder L semittel verwenden Niemals innen reinigen Power supply For a complete list of maintenance and cleaning regulations see the manufacturer s original operating instructions To avoid electric sh...

Page 16: ...20 R hrer Typ Kronenr hrer Durchmesser mm 14 H he mm 12 Material PTFE Heizblock f r geteilte Zellen IKA Item 20015936 Durchmesser mm 150 Material Aluminum eloxiert Gewicht kg 2 1 Max Temperatur C 200...

Page 17: ...e ml 20 Stir bar Type Single cross head Diameter mm 14 Height mm 12 Material PTFE Heating block for divided cells IKA Item 20015936 Diameter mm 150 Material Aluminum anodized Weight kg 2 1 Max tempera...

Page 18: ...18 IKA Werke GmbH Co KG Janke Kunkel Str 10 D 79219 Staufen Tel 49 7633 831 0 Fax 49 7633 831 98 sales ika de www ika com 40004123 20000021616 OMI screening system DE EN 1 1 docx...

Reviews: