Eighth step: Data sending
As we said at the beginning of the document different ways to send data are possible like SMS and FTP. In this part I will
show you the way to do it by FTP. First keep in mind that on the installation location if you already can’t find operator
signal in surface, it will be even more difficult while under a metal cover in the manhole.
Sending by FTP
:
First, you need to:
- Insert in the sensor SIM holder a regular size data sim card with at least 5 Mo/month on your plan. While buying the
card please ask the APN of the operator, as well as the Pin code if any. We will need these information. The cellular
antenna has also to be connected to the connector on top of the sensor.
- Set now your time zone in the
System options
menu:
- After clicking on the “Edit block” button of the Data sending part, choose the sending type (FTP for example) and
define the data sending frequency. You can define several periods by clicking on the key button “show advanced
parameters” and then clicking and the green + icon.
Depending on your configuration you may need to choose a minimum delay between 2 anticipated data sending.