Ihse K471-CT Manual Download Page 18

 

REPEATER/CROSS- REPEATER 

18 

   

Rev. : 09/25/2012

 

4.1  Setup at the Repeater/Cross- Repeater 

After unscrewing and opening the upper shell, please place the device in this orientation: with 
the CATx/fiber connectors to the left and the Fiber connectors to the right (eventually not 
equipped with GBICs).  

The main PCB then will look like this: 

 

 

Use the diagram to locate jumpers. 

Operating mode Repeater or Cross- Repeater 

If you want to alter the mode of operation after the date of purchase, e.g. from Repeater to 
Cross- Repeater or vice versa, you need (probably) to install optical Transceiver (GBICs) and 
reconfigure the device. 

 

Operating Mode 

JP1 

JPA B 

Repeater or Fiber- Cross- Repeater 
 

 

 

CATx/Fiber Cross- Repeater 

 
 

 

 

JP1 

JPA B 

Summary of Contents for K471-CT

Page 1: ...distance and simultaneously convert from one medium to another e g CATx to Multimode This manual will tell you all about your new Repeater Cross Repeater including how to install operate and troubles...

Page 2: ...does the manufacturer assume any liability for damages resulting from the use of the information contained herein The manufacturer reserves the right to change the specifications functions or circuit...

Page 3: ...EMPTY PAGE Rev 09 25 2012 3...

Page 4: ...entation noted in this manual shall be considered in detail The length of the attached CPU or Console Cables must not exceed 3m The use of suggested interconnect cables is mandatory Oberteuringen June...

Page 5: ...irflow Do not place a power supplies directly on top of a unit Do not obstruct a unit s ventilation existing holes To safeguard against personal injury and avoid possible damage to equipment or proper...

Page 6: ...11 3 Installation 12 3 1 Package Contents 12 3 2 Interconnection Cable Requirements 13 3 3 System Setup 14 3 4 Device Views 15 3 5 Diagnostics 16 4 Service Setup 17 4 1 Setup at the Repeater Cross Re...

Page 7: ...scribed in the rest of this manual Install system 1 Connect Local unit to CPU or switch 2 Connect Local unit to Repeater and Repeater to Remote Unit using matching interconnection cable CATx or Fiber...

Page 8: ...t possible 2 2 Glossary The following terms are used in this guide CATx Any Category 5 5e 6 or higher cable solid wires type AWG24 Fiber Singlemode or Multimode fiber cable Singlemode 9 Singlemode fib...

Page 9: ...OVERVIEW Rev 09 25 2012 9 2 3 Example of a Repeater Cross Repeater System Installation as Repeater to double the total allowed distance Installation as Cross Repeater for inhomogeneous cable path...

Page 10: ...de of the Repeater Cross Repeater may have the usual maximum distance e g CATx up to 140m Multimode 50 up to 400m Attention actually DVXi CATx and Fiber devices must not be used assorted This means it...

Page 11: ...Cross Repeater to convert from 2x CATx to 2x Singlemode or back K471 MS Multimode Singlemode Cross Repeater to convert from Multimode to Singlemode or back Zubeh r 473 5G 19 1HE Rackmout Kit to mount...

Page 12: ...you to identify and solve any cabling problems and experiment with the Repeater Cross Repeater more conveniently 3 1 Package Contents You should receive the following items in your extender package al...

Page 13: ...Dualhead devices Please note that the allowed distance will depend on device type AND on used fiber type Recommended cables Multimode type 50 125 allowed distance app 400m 1 300ft Multimode type 62 5...

Page 14: ...this please refer to installation instruction on page 19 If you have bought a Dual Cross Repeater your device will have two CATx connectors and two fiber connectors The units are marked as Local or Re...

Page 15: ...TALLATION Rev 09 25 2012 15 3 4 Device Views Repeater Cross Repeater CATx view Repeater Cross Repeater Fiber view To Local Unit To Remote Unit 5V universal switch mode p s u To Local Unit To Remote Un...

Page 16: ...the LEDs is shown below Diagnostic LEDs at the Repeater Cross Repeater LED Appearance Diagnostics Power LED Red LED Off On Device not ready Device ready Link Status Green LED Blinking On No INTERCONNE...

Page 17: ...sary to setup configuration specials For some applications you may need to open the Local Unit and or the Remote Unit Unscrew the Philips type screws at both sides at the bottom of the device Unscrew...

Page 18: ...ght eventually not equipped with GBICs The main PCB then will look like this Use the diagram to locate jumpers Operating mode Repeater or Cross Repeater If you want to alter the mode of operation afte...

Page 19: ...B Dualhead Cross Repeater Local CATx Dualhead Cross Repeater Remote CATx 4 2 installation instruction Basically you need to pay attention to attach at connectors marked with A only cables which link t...

Page 20: ...s in your devices are plugged incorrect you may alter the configuration easily flap the shackle at the GBIC downwards now pull the GBIC using the shackle out of the cage plug the GBIC with soft force...

Page 21: ...ion where the CATx cable link to the Remote Unit 5 Troubleshooting Monitor There isn t a picture Check the power supply connection at the local and remote unit and at the Repeater Cross Repeater Is th...

Page 22: ...5 2012 Appendix A Example Applications This section illustrates some specific applications using the Repeater Cross Repeater Repeater in Industrial Plant to raise the allowed distance of the interconn...

Page 23: ...ments especially public buildings the signal path may be inhomogeneous This means a part might be based on CATx another part in Multimode The Cross Repeater hereby allow to convert from one medium to...

Page 24: ...f two buildings with CATx Cables Because of this the interconnection must be done in fiber A server from the server room shall be connected with the user console in the plant The Cross Repeater hereby...

Page 25: ...equires 1U Rackspace Blindplates in the list of parts delivered allow to cover unused device positions Rackmount Kit 473 5G List of parts delivered Mounting instruction Align the holes on the base pla...

Page 26: ...ckmount Kit 473 5G allows to mount a different count of devices 1 5 pieces Einbau 1 Ger t mounting 1 device Einbau 2 Ger te mounting 2 devices Einbau 3 Ger te mounting 3 devices Einbau 5 Ger te mounti...

Page 27: ...curs The components involved in the problem that is what type of computers what type of keyboard brand of mouse make and model of monitor type and make of cable etc Any particular application that whe...

Page 28: ...e depending on device RJ45 1000 MBit high speed transmission Wiring according to EIA TIA 568B Gigabit Ethernet Maximum Length of Interconnection Cable CATx CATx Installation cable AWG24 140m 400ft CAT...

Page 29: ...50 m 400m 1 300ft Multimode 62 5 m 200m 650ft Size and Shipping Weight Repeater Cross Repeater 80 x 110 x 29mm 3 x4 3 x1 1 Weight 0 2kg 0 6lb Shipping box 165x165x110mm 6 5 x6 5 x4 3 Weight 0 6 kg 1...

Page 30: ...09 25 2012 Appendix G Connectors Repeater Cross Repeater Connector Pin outs Power Supply Pin Signal inner 5V outer GND CATx Interface Pin out according to EIA TIA 568A 1000BaseT Pin Pin 1 D1 5 D3 2 D...

Page 31: ...NOTES...

Reviews: