Troubleshooting
2011-06-01
53
8.2
Interference
Diagnosis
Possible Reason
Measure
Cable connection
disturbed
Check connection, length and
quality of the DVI-D cable to
monitor, tighten cable
thumbscrews.
Check connection, length and
quality of interconnect cables
between the units.
Incorrect video
display
Wrong DIP switch
settings in combination
with Dual Link
resolutions
Select correct DIP switch settings
(see Chapter 5.1.1, Page 38).
Pos: 68 /806-IHSE/Hilfe im Problemfall/Störung am USB-HID-Anschluss/472-xx @ 6\mod_1304499779915_6.doc @ 50723 @ 2
8.3
USB-HID
Diagnosis
Possible Reason
Measure
Keyboard LEDs
Shift
and
Scroll
are flashing
Keyboard in Command
Mode
Press <Esc> to leave Command
Mode.
No USB-HID device
Connect USB-HID device.
Problems with USB
connection
Check connection of USB cable
to USB-HID device.
Remove DVI and power cable
and restart CON Unit. Connect
power cable first.
USB device
without function
USB-HID device is not
supported
Contact dealer if necessary.
Pos: 69 /806-IHSE/Hilfe im Problemfall/Störung am USB-2.0-Anschluss/472-xx @ 6\mod_1304499836899_6.doc @ 50741 @ 2