background image

SuperiorFireplaces.us.com

126631-01_H

19

CAT NO.

MODEL

DESCRIPTION

BI-FOLD GLASS DOORS

F0975

BDB42

42" - Standard Black Finish (Bungalow Only)

F0976

BDB42B

42" - Standard Brushed Brass Finish (Bungalow Only)

F0977

BDB42P

42" - Standard Platinum Finish (Bungalow Only)

DOUBLE WALL PIPE

   

F0895

12-8DM

12" Section Double Wall Pipe Snap Lock

F0896

18-8DM

18" Section Double Wall Pipe Snap Lock

F0897

24-8DM

24" Section Double Wall Pipe Snap Lock

F0898

36-8DM

36" Section Double Wall Pipe Snap Lock

F0899

48-8DM

48" Section Double Wall Pipe Snap Lock

F0881

12-8HT

12" Section Hi-Temp Double Wall Pipe Snap Lock

F0882

18-8HT

18" Section Hi-Temp Double Wall Pipe Snap Lock

F0883

24-8HT

24" Section Hi-Temp Double Wall Pipe Snap Lock

F0884

36-8HT

36" Section Hi-Temp Double Wall Pipe Snap Lock

F0885

48-8HT

48" Section Hi-Temp Double Wall Pipe Snap Lock

30° OFFSET AND RETURN

F0900

30E-8DM

30 Degree Offset and Return

F0886

30E-8HT

30 Degree Hi-Temp Offset and Return

OPTIONAL OUTSIDE AIR KIT FOR SIDEWALL INSTALLATION

F1091

AK4

Complete Outside Air Kit w/Collars Hood & 3' Flex

OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION

F1093

AK4F

Outside Air Kit Collar, Hood & 3' Flex for Floor Venting

STORM COLLAR

F0915

SC1-1

Storm Collar

FIRESTOP SPACER

F0907

3600FS-8DM-1 1" Clearance Firestop Spacer

ROOF FLASHING

F0909

V6F-8DM

Roof Flashing 0 to 6/12 Pitch (30" Base)

F0910

V12F-8DM

Roof Flashing 6/12 to12/12 Pitch

ACCESSORIES  

Continued

Summary of Contents for Superior Fireplaces Merit WRT2042WS

Page 1: ...CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L...

Page 2: ...ufactured or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local bui...

Page 3: ...oseasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT...

Page 4: ...LL BOARD NOT LESS THAN 12 305 mm TO PERPENDICULAR SIDEWALL 0 0 MM TO BOTTOM 12 305 mm EACH SIDE GAS LINE KNOCK OUT GAS LINE KNOCK OUT RIGHT SIDE LEFT SIDE AIR KIT KNOCK OUT 8 1 4 210 mm 8 1 4 210 mm 2...

Page 5: ...ling flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extensio...

Page 6: ...top opening of fireplace NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material may come up to side edge of black metal face of fireplace if projection from fro...

Page 7: ...r through a sidewall AK4 See Figure 7 for instruction of operating air kit CAUTION Combustion air inlet ducts shall not terminate in attic space The maximum height for the air vent can not exceed 3 fe...

Page 8: ...above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48 length of double wall pipe see offset chart page 9 and Figure...

Page 9: ...bow Return Elbow Return Elbow Return Elbow Return Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m C...

Page 10: ...oftheroof Pitchisthedistancetheroofdrops overagivenspan usually12 A6 12pitchmeansthattheroofdrops 6 for each 12 measure horizontally down from roof rafters 3 Use roof opening chart Figure 14 page 11 t...

Page 11: ...stor Fireplace system must be terminated with listed round top or chase terminations In any case refer to installation instructions supplied with termination Terminations approved for this fireplace a...

Page 12: ...shroud is to be installed contact manufacturer for specifications Figure 18 Multiple Chase Installation 10 3 05 m 10 3 05 m 2 0 61 m Min 2 0 61 m Min 3 0 92 m Min 3 0 92 m Min Level of Flue Gas Outle...

Page 13: ...ment Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Page 14: ...ireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too large a fire is built or if combustion air gate is not completely open The follow...

Page 15: ...used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the...

Page 16: ...16 PARTS WOOD BURNING FIREPLACE MODELS WRT2042WS WRT2042WSI WCT2042WS WCT2042WSI MODEL CAT NO WRT2042WS F0687 WRT2042WSI F0688 WCT2042WS F0689 WCT2042WSI F0690 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18...

Page 17: ...ly 1 8 Firebox Floor 1 9 Wrapper Bottom 1 10 Front Face Weldment Smooth 1 Front Face Weldment Louvered 1 11 See Page 18 Left Side Brick Liner 1 12 See Page 18 Rear Brick Liner 1 13 See Page 18 Right S...

Page 18: ...IHP dealer to obtain any of these parts Never use substitute materials not ap proved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 4 3 6 5 REFRACTORY STAIN KIT...

Page 19: ...T 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Do...

Page 20: ...UVERS AND SLIP SECTION F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE T...

Page 21: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Page 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Page 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Page 24: ...6631 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Reviews: