background image

IPH: RCL-S-STAT

REV. 3-19-14  Page 8 

SETTING DESIRED ROOM TEMPERATURE

This remote control system can be thermostatically controlled 

when the transmitter is in the THERMO mode (THERMO must 

be displayed on the screen).  To set the DESIRED room 

temperature, press the MODE button (Fig. 17) to place the 

transmitter into THERMO mode, then press the UP or DOWN 

buttons to select the desired room temperature.  The highest 

SET temperature is 99º Fahrenheit  (32º Celsius).

OPERATIONAL NOTE:  TO CONSERVE BATTERY POWER, 

CHANGES IN ROOM TEMPERATURE ARE AUTOMATICALLY 

UPDATED EVERY TWO MINUTES TO THE TRANSMITTER.

ROOM

SET

Fig. 17 Mode Button

Fig. 18 SET Temperature

The Thermo Mode on the transmitter operates the appliance whenever the ROOM TEMPERATURE varies a certain 

number of degrees from the SET TEMPERATURE.  This variation is called the “SWING” or TEMPERATURE 

DIFFERENTIAL.  The normal operating cycle of an appliance may be 2-4 times per hour depending on how well the 

room or home is insulated from the cold or drafts.  A smaller  “swing number” increases the number of cycles so the room 

temperature is more constant.  A larger “swing number” decreases the number of cycles, which saves energy, in most 

cases.  The factory setting for the “swing number” is 2.  This represents a temperature variation of +/- 2º F  (1º C) between 

SET temperature and ROOM temperature, which determines when the fireplace will be activated.  The “SWING” number 

values are:  1=+ 1º F  (.5º C), 2= + 2º F (1º C) and 3 = + 3º F (1.6º C). 

SETTING THE TEMPERATURE SWING (TEMPERATURE DIFFERENTIAL)

ROOM

SET

1.  To change the temperature “SWING” setting (1-3), press  

     the TIMER/TIME and DOWN buttons simultaneously to 

     display the current “SWING” setting in the SET TEMP  

     frame.  The letter “S” will display in the ROOM TEMP frame  

     on the LCD screen.  

2.  Press the UP or DOWN button to change the temperature  

     differential or “SWING” (1-3).  See above for 1-3 “SWING”  

     temperature valves. 

3.  To store the “swing number press the SET button or allow  

     15-seconds to lapse, and the new “swing number’ will be  
     automatically programmed.

 

Fig. 19 Timer/Time & Down    

            Buttons

Fig. 20 Swing Temperature

The operation of the factory set “THERMO SWING” can be checked by adjusting the SET TEMP 2º F above or below the 

room temperature.  This will cause the system to turn 

ON

 or 

OFF

.  Normally the system will only respond to temperature 

changes every two minutes.  Manually changing the SET temperature will activate the system in less than 10-seconds.  

If the “SWING” is changed, then a new room temperature differential will respond.  Remember the Factory setting of the 

“SWING” temperature is 2º F.

MANUAL CHECK OF “ SWING” OR TEMPERATURE DIFFERENTIAL

ADDITIONAL PROGRAMMING OF THE TRANSMITTER

MODE

UP

DOWN

COVER CLOSED

TIMER

TIME

UP

MODE

DOWN

SE

T

P/N 900257-00 Rev. A

Summary of Contents for RCL-S-STAT

Page 1: ...s of the batteries as indicated on the casing When the batteries are inserted the screen in figure 2 with similar numbers will display Note If a LOW battery icon appears on the screen check the positi...

Page 2: ...OWN buttons to program a new setting If no change is made to flashing digits within 15 seconds the system will complete the procedure last programmed and reset the display to its normal state SETTING...

Page 3: ...tter With the slide switch in the OFF position away from the LEARN button the system is OFF It is suggested that the slide switch be placed in the OFF position if you will be away from your home for a...

Page 4: ...f the receiver or remove the black wires and install wires directly to the receiver Be sure no splices measure longer than 20 feet and allow ample wire to remove the receiver for annual battery replac...

Page 5: ...ONIC SPARK IGNITIONS The remote control receiver can be connected in series to a 24VAC transformer to the TR transformer terminal on the ELECTRONIC MODULE Connect the hot wire from the 24VAC transform...

Page 6: ...E button on the transmitter to change the system to ON The spark electrode should begin sparking to ignite the pilot After the pilot is lit the main gas valve should open and the main gas flame should...

Page 7: ...TING MODES the transmitter sends an RF signal every fifteen 15 minutes to the receiver indicating that the transmitter is within the normal operating range of 20 feet Should the receiver NOT receive a...

Page 8: ...variation of 2 F 1 C between SET temperature and ROOM temperature which determines when the fireplace will be activated The SWING number values are 1 1 F 5 C 2 2 F 1 C and 3 3 F 1 6 C SETTING THE TEMP...

Page 9: ...y Fig 22 At this time approximately two weeks of battery power remains until the transmitter may experience partial or complete loss of functions ROOM SET Fig 22 Low Battery Sign CHILDPROOF LOCK OUT C...

Page 10: ...eceiver beeps when the MODE button is depressed on the transmitter they are communicating Note The receiver only beeps in ON OFF modes No beeping occurs from ON to Thermo mode If the receiver does not...

Reviews: