![IHP PCBE-325 Quick Start Manual Download Page 4](http://html1.mh-extra.com/html/ihp/pcbe-325/pcbe-325_quick-start-manual_4084167004.webp)
127192-01B
4
IHP.us.com
Figure 7 - Applying English and French Conversion Labels
Over Existing Certifi cation Labels on Lighting Instruction Plate
French This Side
English This Side
VE N
TE D
G A
S FIR
E PL
AC E
HE
ATE
R
Conv
ersion
Kit Model
PCD
M-36R
T
Type
of G
as
Propane
/LP
Minim
um
Inlet S
upply P
ressur
e
11.0"
w.c.
For
Purpose
of In
put
Adjustm
en t
Man
ifold
Pressur
"
0
.
0
1
e
w.c.
O utput R
atin
g
Max.
13,000 Btu
/h
Input
Rat
in g
Max.
20,000
Btu/h
(0-4500 Ft)
Min.
13,000 Btu/h
Th
is A
ppliance is Eq
uipped
with an S
.I.T. N
ova M
odel
0.820.651
Valve
C om
plies
with
AN
S Z21.88
-200
0
C SA
2.33-200
0
Ven
ted
G as
Fire
place
Heater
116
63
5-01
Previou
s M
ode
l #
___
__
___
___
__
C
US
Conversion Labeling and Placement
1. Apply the English and French conversion labels over existing certifi -
cation labels
(see
Figure 7
)
. Existing certifi cation labels are located
on the lighting instruction plate inside the gas valve compartment
area. With permanent ink, print the previous model number on the
label in the space provided
(see
Figure 8
).
2. After fi lling in the data required on the conversion information label,
affi x it to the fl oor of the appliance where it is easily seen when the
control cover is removed
(see
Figure 9
).
Figure 9 - Conversion Information Label
CONVERSION INFORMATION LABEL
This appliance was converted on
___ - ___ - ___ to ______________ gas
with Kit No. _______________________
by
_____________________________
_____________________________
_____________________________
(name and address of organization making
this conversion), which accepts the
responsibility that this conversion has been
properly made.
106080-01
56060
Day Month Year
Lighting
Instruction
Plate
Figure 8 - Print Previous Model Number on
Conversion Labels
Figure 10 - Converting Pilot Orifi ce
VENTED GAS FIREPLACE
Conversion Kit Model
Type of Gas
Previous Model #
C
US
PILOT ORIFICE CONVERSION
1. Remove the pilot hood assembly from barrel using a 7/16” open
end wrench
(see
Figure 10
).
2. Remove the pilot orifi ce from inside the barrel with tweezers or a
pair of needle nose pliers.
3. Replace
pilot
orifi ce with propane/LP orifi ce supplied with this kit.
The number 14 is stamped on the sleeve for identifi cation. Insert
the open end of the new pilot orifi ce into the barrel and thread the
pilot hood back onto the barrel.
4. Tighten the hood using the 7/16” open end wrench until the hood
is fully seated and in-line with the bracket.
IMPORTANT
: Be careful not to bend or kink the aluminum tubing
during conversion. Make sure the pilot hood and orifi ce are properly
mated and aligned after fi nishing this conversion.
Pilot Hood
Pilot Orifice
Barrel Clip
Pilot Bracket
7/16" Hex
Wrench
f i r e - p a r t s . c o m