Final Preparation

1.  Replace any vermiculite and ember material if displaced. Refer to 

Ember and Pan Material Placement

 in owner’s manual.

2.  Reinstall logs starting with the rear log, front logs, then remaining 

top logs. Refer to 

Log Placement

 in owner’s manual.

3.  Leak check gas control and any connections you’ve made before 

operating appliance. Refer to 

Gas Supply Hook-up

 in owner’s manual.

4.  Replace refractory access panel and volcanic stone.
5.  Replace glass doors if previously installed. Refer to 

Installing Optional 

Glass Doors

 in owner’s manual.

6.  Using a manometer, test the inlet and manifold gas pressures. 

Inspect for proper burner fl ame appearance

 (see 

Figure 11

).

The conversion is now complete. To operate your fi replace, refer to 

Operating Fireplace

 in your appliance owner’s manual.

 WARNING 

Test all gas piping and connections for leaks after 
installation or servicing. Correct leaks at once.

 WARNING 

Never use an open fl ame to check for a leak. Apply 
noncorrosive leak detection fl uid to all joints. Bubbles 
forming show a leak. Correct all leaks at once.

Figure 11  - Inspect for Proper Burner Flame Appearance

No Blue Flame 
Center

Soot at 
Flame Tip

Dark Orange 
Flame

IMPROPERLY 

BURNING FLAME

Soot above 
Flame Tip

No Soot at 
Flame Tip

PROPERLY

BURNING FLAME

Semi-Transparent 
Yellow Flame 

Blue Flame 
Center

REFERENCE INFORMATION

Inlet Gas Supply Pressure 

Fuel #

Minimum

Maximum

Propane

11.0” WC (2.74 kPa)

13.0” WC (3.23 kPa)

Table 1

Manifold Gas Supply Pressure

Fuel #

Pressure

Propane Gas

10.0” WC / (2.49 kPa)

Table 2

Main Burner Orifi ce Sizes

Fireplace Model

Drill Size

Propane

BRT2032

#56

Table 3

BTU Input

Models

Propane Gas / LP

High Rate

Low-rate

BRT2032

15,000

n/a

Table 4

f i r e - p a r t s . c o m

Summary of Contents for PCBE-324

Page 1: ...ordance with the manufac turer s instructions and all applicable codes and requirements of the authority having jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency performing this installation is responsible for the proper insta...

Page 2: ...e installer and adhered to the appliance at the time of the conversion Contact your local gas supplier for deration requirements for your area CAUTION The gas supply shall be shut OFF prior to discon necting the electrical power before proceeding with the conversion ATTENTION Avant d effecteur la conversion coupez d abord l alimentationengaz ensuite coupezl alimentation electrique Figure 1 Removin...

Page 3: ...rench on fitting to prevent turning burner tube 9 Retighten flare fitting on flexible manifold tube with the 3 4 open end wrench and 7 8 back up wrench 10 Reattach pilot shield onto burner bracket with screw removed in step 1 3 8 Deep Socket Propane LP Gas Orifice Propane LP Gas Air Mixer Fitting 3 8 Flare Fitting Natural Gas Orifice Fitting Burner Bracket Flange Burner Tube 7 8 Back Up Wrench Pil...

Page 4: ...d Figure 9 Conversion Information Label CONVERSION INFORMATION LABEL This appliance was converted on ___ ___ ___ to ______________ gas with Kit No _______________________ by _____________________________ _____________________________ _____________________________ name and address of organization making this conversion which accepts the responsibility that this conversion has been properly made 106...

Page 5: ...perating Fireplace in your appliance owner s manual WARNING Test all gas piping and connections for leaks after installation or servicing Correct leaks at once WARNING Never use an open flame to check for a leak Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once Figure 11 Inspect for Proper Burner Flame Appearance No Blue Flame Center Soot a...

Page 6: ...___________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________________________...

Page 7: ...___________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________________________...

Page 8: ...P reserves the right to make changes at any time without notice in design materials specifica tions prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1508 Elm Hill Pike Suite 108 Nashville TN 37210 fire parts com ...

Reviews: