IHP.us.com
126913-01A
9
INSTALLATION
Continued
PRESSURE TESTING APPLIANCE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 12, page 8).
2. Open main gas valve located on or near gas meter for
natural gas or open propane/LP supply tank valve.
3. Make sure control knob of appliance is in the OFF position.
4. Check all joints from gas meter to equipment shutoff valve
for natural gas or propane/LP supply to equipment shutoff
valve for propane/LP (see Figure 13, or Figure 14, page 8).
Apply noncorrosive leak detection fl uid to all joints. Bubbles
forming show a leak.
5. Correct all leaks at once.
6. Light appliance (follow the
Operation
instructions accom-
panying your burner system). Check all other internal joints
for leaks.
7. Turn off appliance (see
To Turn Off Gas to Appliance
, follow
the instructions accompanying your burner system).
ADDING PAN MATERIAL
Two pan materials are included with the MFEB. Lava rock,
small grey/black rock is for use on the burner pan for outdoor
applications. Vermiculite, light tan - lightweight material, is
for use on the burner pan for indoor applications.
Apply the material for your application on the burner pan by
spreading it evenly across the burner pan so that it is level
with the edges of the burner pan and covers the round, tu-
bular burner.
ADDING EMBER MATERIAL (INDOORS ONLY)
Two ember materials are included with the MFEB. Apply
rock wool glowing embers by spreading a 1/2 inch layer of
rock wool on top of the pan material. Pull any clumps apart
so that the fl ames will pass through the pieces. Apply Plati-
num Bright Embers by placing the pieces randomly over the
rock wool.
WARNING: Failure to position the parts in
accordance with these diagrams or failure to
use only parts specifi cally approved with this
appliance may result in property damage or
personal injury.
OPERATION
CAUTION: Follow the OPERATION instruc-
tions accompanying your burner system for
critical safety information and for instructions
on how to operate your burner system.
SPECIFICATIONS
MAGNIFLAMEOD24PE, MAGNIFLAMEOD24PM,
MAGNIFLAMEOD30PE, MAGNIFLAMEOD30PM,
MFBOD24MP, MNF24OPE, MNF24OPM,
MNF30OPE, MNF30OPM
Burner systems with MFEB optional ember burner installed.
• Rating (Variable): 50,000/70,000 Btu/Hr
• Type Gas: Propane/LP
• Manifold Pressure: 10.0" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
*For purpose of input adjustment
MAGNIFLAMEOD24NE, MAGNIFLAMEOD24NM,
MAGNIFLAMEOD30NE, MAGNIFLAMEOD30NM,
MFBOD24MN, MNF24ONE, MNF24ONM,
MNF30ONE, MNF30ONM,
Burner systems with MFEB optional ember burner installed.
• Rating (Variable): 40,000/65,000 Btu/Hr
• Type Gas: Natural
• Manifold Pressure: 3.4" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
REPLACEMENT PARTS
Normally, all parts should be ordered through your IHP distributor
or dealer. Parts will be shipped at prevailing prices at time of order.
NEVER USE SUBSTITUTE MATERIALS. USE OF NON-APPROVED PARTS
CAN RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS.
When ordering repair parts, always give the following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any questions concerning the
installation or application of this appliance, please contact your dealer.
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. Please contact your IHP dealer for any ques-
tions or concerns. When contacting your dealer please have
your model and serial numbers of your appliance ready. You
can also visit our web site at IHP.us.com.
f i r e - p a r t s . c o m