IHP GCKSMS557051NP Quick Start Manual Download Page 4

4

Figure 5  - Burner Flame Appearance

Figure 6  - Pilot Flame Appearance

No Blue Flame 

Center

Soot at 

Flame Tip

Dark Orange 

Flame

IMPROPERLY 

BURNING FLAME

Soot above 

Flame Tip

No Soot at 

Flame Tip

PROPERLY

BURNING FLAME

Semi-Transparent 

Yellow Flame 

Blue Flame 

Center

THIS APPLIANCE HAS BEEN CONVERTED TO:

THIS APPLIANCE HAS BEEN CONVERTED TO:

INPUT BTU / HR - ##, ###

MANIFOLD PRESSURE - 10”

ORIFICE SIZE: ## (#.##”)

INPUT BTU / HR - ##, ###

MANIFOLD PRESSURE - 3.5”

ORIFICE SIZE: ## (#.##”)

PROPANE GAS

NATURAL GAS

Figure 8 - Affix Gas Conversion Sticker

Figure 9 - Fill Out and Affix Gas Conversion Form Sticker

Affix the supplied gas conversion sticker next to the rating 

plate label stating this unit has been converted to another gas.

Fill out, then affix the supplied gas conversion form sticker 

next to the rating plate.

Pilot

Hood

Sensor

Ignitor

Igniter

Pilot Hood

Thermocouple

Pilot Hood

Thermocouple

Igniter

Inlet Gas Supply Pressure 

Fuel #

Minimum

Maximum

Natural Gas

5” WC (1.25 kPa)

10.5” WC (2.61 kPa)

Propane

11.0” WC (2.74 kPa)

13.0” WC (3.23 kPa)

Table 4

Manifold Gas Supply Pressure

Fuel #

Pressure

Natural Gas

3.5” WC (0.87 kPa)

Propane

10.0” WC (2.49 kPa)

Table 5

BTU Input

Millivolt Models

Natural Gas

Propane Gas

High 

Rate

Low

Rate

High 

Rate

Low

Rate

DRT4040-B, Altair 40-B

28,000

20,000

25,000

18,000

DRT4045-B, Altair 45-B

31,000

21,000

31,000

20,000

Table 7

REFERENCE INFORMATION

 THIS APPLIANCE HAS BEEN CONVERTED ON  (MM/DD/YY) 

________________ TO _____________ GAS WITH KIT NO.

_______________ BY  (NAME AND ADDRESS OF ____________

_______________________________________ ORIGANIZATION

MAKING THIS CONVERSION), WHICH ACCEPTS THE

RESPONSIBILITY THAT THIS CONVERSION HAS BEEN

 PROPERLY MADE.”

  “CET APPAREIL ELAIT CONVERT SUR  LE  (MM/DD/YY)

________________ A _______________ GAZ AVEC

L’EQUIPEMENT NO. ____________________ PAR  (NOM ET 

ADRESSE_____________________________________________

D’ORGANISATION FAISANT CETTE CONVERSION), QUI ACCEPTE 

LA RESPONSABILITE QUE CETTE CONVERSION A ETE FAITE 

CORRECTEMENT”.

LB-104682A

Burner Orifice Sizes

Fireplace Millivolt Models

Natural Gas - drill size

Propane - drill size

DRT4040-B, Altair 40-B

#42 (0.0935”) Rear,
#55 (0.052”) Front*

#55 (0.052”) Rear,

#70 (0.028”) Front *

DRT4045-B, Altair 45-B

#41 (0.096”) Rear,

#55 (0.052”) Front*

#53 (0.0595”) Rear,

#70 (0.028”) Front *

Table 6

* Standard size installed at factory

Printed in U.S.A. © 2016 Innovative Hearth Products

P/N  900792-00  Rev. NC  08/2016

IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for 

fireplace code information.

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Summary of Contents for GCKSMS557051NP

Page 1: ... fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency performing this installation is responsible for the proper installation of this kit and assumes responsibility for this conversion The installation is not proper and complete until the operation of the converted appliance is checked as specified in the ma...

Page 2: ...E and discon nect power supply at the circuit breaker Ensure fireplace is cold 2 Open the lower control compartment at the bottom front of the fireplace door by holding the control compartment door then rotate it away from the fireplace 3 Remove the barrier and front glass door frame from the fire place 4 Remove the logs If necessary remove the log grate NOTE Exercise care so as not to break the l...

Page 3: ...E Always test pressures with the valve regulator control at the highest setting 18 Affix the appropriate conversion labels see Figures 8 and 9 19 Replace door barrier and optional facade if installed Ensure proper operation with both door and barrier in place NOTE A BARRIER DESIGNED TO REDUCE THE RISK OF BURNS FROM HOT VIEWING GLASS SHALL BE USED DURING OPERA TION OF THIS FIREPLACE FOR THE PROTECT...

Page 4: ...T4040 B Altair 40 B 28 000 20 000 25 000 18 000 DRT4045 B Altair 45 B 31 000 21 000 31 000 20 000 Table 7 REFERENCE INFORMATION THIS APPLIANCE HAS BEEN CONVERTED ON MM DD YY ________________ TO _____________ GAS WITH KIT NO _______________ BY NAME AND ADDRESS OF ____________ _______________________________________ ORIGANIZATION MAKING THIS CONVERSION WHICH ACCEPTS THE RESPONSIBILITY THAT THIS CONV...

Reviews: