901175-00 NC
8
ihp.us.com
OUTDOOR SPACES - An appliance is considered to be out-
doors if installed with shelter no more inclusive than:
1� with walls on all sides, but with no overhead cover;
2� within a partial enclosure that includes an overhead cover
and no more than two sidewalls� The sidewalls may be
parallel, as in a breezeway, or at right angles to each
other; or
3� within a partial enclosure that includes an overhead cover
and three sidewalls, as long as 30 percent or more of
the horizontal periphery of the enclosure is permanently
open�
WARNING: Failure to position the parts in accor-
dance with these diagrams or failure to use only parts
specifically approved with this appliance may result
in property damage or personal injury.
INSTALLING LOGS AND MEDIA PLACEMENT
DUALBURNEROD24/30/36-N BURNER SYSTEM
LOG COMPATIBILITY CHART
Burner System Model
Log Sets For Use With This Burner System
DUALBURNEROD24N
ASHTONWHITEBIRCH24
OZARKCHARREDOAK24
SMOKYWEATHEREDOAK24
DUALBURNEROD30N
ASHTONWHITEBIRCH30
OZARKCHARREDOAK30
SMOKYWEATHEREDOAK30
DUALBURNEROD36N
ASHTONWHITEBIRCH36
OZARKCHARREDOAK36
SMOKYWEATHEREDOAK36
LOG/MEDIA PLACEMENT
It is very important to install these logs exactly as instructed� Do not
modify logs�
Please refer to specific Log Placement Guides placed
inside each Log Set
�
Lava Rock
Ember Placement
MEDIA PLACEMENT - NATURAL GAS
Tear ember material into pieces the size of a corn kernel and place
fingernail deep�� Use either a comb or brush to achieve this� The
smaller the piece, the better the ember glow� Spread the embers
across the front burner and fill up the pan� The front burner should
be completely covered� Dump lava rock around the burner covering
the hearth�
WARNING: Test all gas piping and connections,
internal and external to unit, for leaks after installing
or servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for
a leak. Apply a noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak. Correct all
leaks at once.
CHECKING GAS CONNECTIONS