10

Filter should be changed every 6 months or sooner if filter discolors.

• 

Remove filter by turning the filter cover anticlockwise and pulling out 

of the unit. Discard old filter.

• 

Replace with a new filter Additional filters should be purchased from 

your provider.

• 

Push new filter into position. Turn the filter cover clockwise to fit in 

position.

• 

You can use a small coin or flat screwdriver to open filter.

Caution: 

Do not reuse or wash filter or substitute any other material such 

as cotton for a air-inlet filter. It will result in compressor damage.

UNIT MAINTENANCE

All parts of the nebulizer kit, except tubing, should be cleaned according 

to the following instructions. Your physician may specify a certain cleaning 

procedure. If so, follow their recommendations.

To  prevent  possible  risk  of  infection  from  contaminated 

medication, cleaning of the nebulizer is recommended after each 

aerosol treatment. Disinfecting is recommended once a day.

Clean after Every Use

With power switch in the “OFF” position, unplug power plug.

Disconnect tubing from the air-inlet connector and set aside.

Disassemble mouthpiece, or mask from cap. Open nebulizer by turning 

cap counter clock wise and removing baffle.

Wash all items, except tubing, in a warm water / dishwashing detergent 

solution. Rinse under warm tap water, remove detergent residue. Allow 

to air dry.

Disinfect Daily

Using a clean container or bowl, soak items for 30 minutes in three parts 

warm water & one part medical bacterial-germicidal disinfectant available 

through your provider. With clean hands, remove items from disinfectant 

solution, rinse under warm tap water, and air dry on clean paper towel. 

Summary of Contents for iWind

Page 1: ...NEBULIZER SYSTEM compressor model iWind...

Page 2: ...COPD and other respiratory ailments in which an aerosolized medication is required during therapy Aerosol easily and quickly comes to both upper and lower respiratory tracks Before starting to use the...

Page 3: ...zer systems are used by the patients with acute respiratory diseases obstructive pulmonary disease chronic inflammatory processes in respiratory passages such as chronic bronchitis bronchial asthma in...

Page 4: ...hey are thoroughly disinfected and dried and stored in a clean location in a sealed bag Do not store the nebulizer kit parts while there is moisture medicine cleaning solution or medication remaining...

Page 5: ...ear chil dren or invalids or persons who cannot express their consent Do not use the device while sleeping or if drowsy Keep the device and accessories out of the reach of unsupervised in fants and ch...

Page 6: ...time and check that there are no problem In particular be sure to check the following That the nozzle or air tube are not damaged That the nozzle is not blocked That the compressor operates normally W...

Page 7: ...Air tube 6 Child mask 7 Power switch 8 Filter 9 Air outlet connector 10 Carrying handle space 11 Power cord 12 Power plug 13 Ventilation slot CARRYING OUT NEBULIZING THERAPY Assembling the Unit opera...

Page 8: ...down in medication cup Open the medicine cup cap and put the medicine from medicine vial into the medicine cup Close the medicine cup cap tightly Attach one end of the tube to the medicine cup Connec...

Page 9: ...more than rated time See instrument bottom panel for details Allow specified off period for instrument to cool before resuming use The nebulizer is made with high quality of plastic which is safe for...

Page 10: ...ocedure If so follow their recommendations To prevent possible risk of infection from contaminated medication cleaning of the nebulizer is recommended after each aerosol treatment Disinfecting is reco...

Page 11: ...ion after each use Clean the nebulizer kit before using for first time after purchase Compressor leaning With power switch in the OFF position unplug power from wall outlet plug Wipe outside of the co...

Page 12: ...e bottom panel The device is abnormally loud Air filter is covered or dirty Attach the air filter cover correctly The device is very hot ompressor are covered ventilation slots are blocked Do not cove...

Page 13: ...ne Note If the suggested remedy does not solve the problem do not try to repair the device Shut off the device for about 1 hour and then restart the machine If the problem persists contact your author...

Page 14: ...p Mouthpiece The specifications and the outer design are subject to change for im provement reasons without previous notice Electromagnetic compatibility This aerosol therapy unit is designed to meet...

Page 15: ...rectly connected to the public low voltage power sup ply network which is used to supply homes and buildings Voltage fluc tuations flicker IEC 61000 3 3 Complies Emissions RC CISPR 14 1 Complies Nebul...

Page 16: ...th the device and those parts subject to normal wear and tear The warranty is only valid upon presentation of the warranty card with purchase date and stamp of trade organization Should the unit be da...

Reviews: