background image

 

 

INTRODUCTION AND INTENDED USE 

Thank you for selecting iHealth Pulse Oximeter product.   
 
PO3 is intended to measure blood oxygen saturation (SpO

2

%)(the amount of oxygen 

in your blood) and pulse rate(bpm). It is designed for adult and can be used in family, 
homecare,  commdevicey  care.  The  PO3  is  a  medical  device  and  is  not  intended  to 
diagnose or treat any medical condition or disease. 
 
This Bluetooth pulse oximeter can be used with an iPod, iPhone or iPad. 
 
iPhone and iPod touch are trademarks of Apple Inc., registered in the U.S. and other 
countries. iPad is a trademark of Apple Inc. 
 
The iHealth Bluetooth pulse oximeter is designed for the following models: 
iPod touch 5th generation 
iPhone 4S 
iPhone 5 
New iPad 
iPad 4 
 
The iOS version of these device should be V5.0 or higher. 
 
iHealth is a trademark of iHealth Lab Inc. 

CONTENTS AND DISPLAY INDICATORS 

 

 

Summary of Contents for PO3

Page 1: ...D INTENDED USE 2 CONTENTS AND DISPLAY INDICATORS 2 PRODUCT DESCRIPTION 3 SPECIFICATIONS 3 CAUTIONS 3 Cautions 3 USING YOUR PULSE OXIMETER 5 CARE AND MAINTENANCE 6 TROUBLESHOOTING 6 IMPORTANT INFORMATI...

Page 2: ...ded to diagnose or treat any medical condition or disease This Bluetooth pulse oximeter can be used with an iPod iPhone or iPad iPhone and iPod touch are trademarks of Apple Inc registered in the U S...

Page 3: ...60nm 880nm 5 SpO2 Measuring Range 70 99 6 Average Root Mean Square ARMS of SpO2 Accuracy 70 99 2 digits 70 no definition 7 Pulse Rate Measuring Range 30 250bpm 8 Pulse Rate Accuracy 2bpm or 2 larger o...

Page 4: ...ble environment oxygen enriched environment 11 Do not use the pulse oximeter outside the specified operating and storage temperature ranges 12 Field strengths from fixed transmitters such as base stat...

Page 5: ...STEP 4 Launch the app and login then the app should connect to the pulse oximeter if connect successfully the app should show the measuring page NOTE When you use app for the first time you should cre...

Page 6: ...e alcohol directly on or into the device 2 Do not drop this device or subject it to strong impact 3 Avoid high temperature and solarization Do not immerse the device in water as this will result in da...

Page 7: ...l interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this product does cause harmful interference to radio or televisio...

Page 8: ...8 SERVICE CENTER iHealth Lab Inc Mountain View CA 94040 USA 1 855 816 7705 Toll Free www iHealth99 com...

Reviews: