- 6 -
10.2013
Layout & configuration
robolink
®
Igus Motion Editor
igus GmbH
Spicher Strasse 1a, 51147 Cologne, Germany
Tel: +49-(0)2203 / 9649-7331
eMail: [email protected]
4) Nanotec SMCI47-S NanoPro configuration
1.
Set motor address to "1" as shown
2.
Using a RS485 converter cable, connect the control with PC/laptop
3.
Supply control with 48V DC
4.
Install and start NanoPro
5.
Always deny the message "Read configuration from control"!
6.
Select the COM interface of the RS485 converter under the "Communication" tab
7.
Update firmware: System → Change Firmware → Select Firmware
→ RS485 / 04-02-2011
8.
Verify successful update
9.
Reset the control to the default condition under the "Mode" tab
10.
Restart control
11.
Motor → delete motor
12.
Motor → Add Motor → Address "1"
(this step is necessary to reset all changed software settings)
13.
Status display tab → acNvate autostart → save data → write configuraNon to control
(briefly switch to mode tab if the autostart function is missing)
14.
Close programme, turn off control, and repeat steps 1-14 for additional controls