External Signal Exchange
86/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
6.4.7 Statusword
The Statusword provides general operating state information of the dryve D1.
Bit assignment of Statusword 6041h
Bit Description
Different meaning "Mode Specific"
Homing
Profile Position
Profile Velocity
0
Ready to Switch On
-
-
-
1
Switched On
-
-
-
2
Operation Enabled
-
-
-
3
Fault
-
-
-
4
Voltage Enable
-
-
-
5
Quick Stop
-
-
-
6
Switch On Disabled
-
-
-
7
Warning
-
-
-
8
Manufacturer Specific
-
-
-
9
Remote
0: DI 7 logical 0
0: DI 7 logical 0
0: DI 7 logical 0
1: DI 7 logical 1
1: DI 7 logical 1
1: DI 7 logical 1
10
Target Reached
0: Target not reached
0: Velocity not reached
1: Target reached
1: Velocity reached
11
Internal Limit Active
-
-
-
12
Operation mode specific
0: Wait for new setpoint
0: Speed ≠0
1: Setpoint applied
1: Speed =0
13
Operation mode specific
-
-
-
14
Manufacturer Specific
-
-
-
15
Manufacturer Specific
-
-
-
Bit assignment, Statusword 6041h, data package
Meaning
Bit 15 → Bit 0
xxxx xx1x x0xx 0000b
Not Ready to Switch On
xxxx xx1x x1xx 0000b
Switch On Disabled
xxxx xx1x x01x 0001b
Ready to Switch On
xxxx xx1x x01x 0011b
Switched On
xxxx xx1x x01x 0111b
Operation Enabled
xxxx xx1x x00x 0111b
Quick Stop Active
xxxx xx1x x0xx 1111b
Fault Reaction Active
xxxx xx1x x0xx 1000b
Fault