background image

 

 

6- IMPORTANT SAFETY INFORMATION 
 
 

 

6.1 Fire prevention:  
 

Replace any blown or damaged fuses only with those of identical value: T 2A 250V. 
 
 

6.2 Prevention from electric shock: 
 

High voltage is present inside the unit. Unplug the unit prior to performing any 
operation which involves touching the inside of the unit. 
This equipment must be grounded, do not connect to non-grounded supplies. 
The use of a thermal magnetic circuit breaker is recommended for each TEATRO LED 
SPOT 100 unit. Use only AC supplies 100-240V  50-60 Hz.  
The unit should never be located in position exposed to rain or in areas of extreme 
humidity. 
A good air ventilation is essential for proper equipment work.  
 
 

6.3 Safety: 
 

Risk Group 2 product according to EN 62471. 
CAUTION. Do not look directly into the light output. May be harmful to the eyes and 
skin. 
 
Do not stare at the operating light source.  
The light source contained in this luminaire shall only be replaced by the manufacturer 
or his service agent or a similar qualified person. 
The unit is not for household use and must be installed by a qualified electrician or 
experienced person. 
The external surface of the unit may exeed 60°C; never handle the unit until at least 5 
minutes have elapsed since the unit was turned off. 
Never install the unit in an enclosed area lacking sufficient air flow. 
 
The ambient temperature should not exeed 40°C.  
 

 
6.4 Waste Electrical and Electronic equipment (WEEE) directive: 
 

The unit, accessories and packaging should be sorted for environmetal-friendly 
recycling. 
For EC countries: according to the European Directive 2012/19/EC for Waste 
Electrical and Electronic Equipment and its implementation into national right, 
luminaires that are no longer usable must be collected separately and disposed of in 
an environmentally correct manner. 

 
 
 
 
 
 
 
 
 

!

Summary of Contents for TEATRO LED SPOT 100 PC

Page 1: ......

Page 2: ...products or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d vent...

Page 3: ...prevention 7 6 2 Prevention of electric shock 7 6 3 Safety 7 6 4 Waste Electrical and Electronic Equipment directive 7 7 INSTALLATION 8 8 INPUT OUTPUT CONNECTIONS 8 9 DMX SIGNAL CONNECTION 9 9 1 DMX...

Page 4: ...EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE 2 GENERAL WARNING Read the instruction contained in this user manual carefully as they give important information regarding safety during installat...

Page 5: ...ol DMX 512 or Manual control 6 DMX channels Default or 2 DMX channels 4 digit 7 segment LED display 4 soft keys Power supply Full range 100 240Vac 50 60 Hz Consumption 150W Max Connections Power suppl...

Page 6: ...6 DIMENSIONS 5 ACCESSORIES As standard Filterframe black finishing already installed on the projector code 02M00416 46 Optional on request Barndoor black finishing code 03 TBD01...

Page 7: ...to the eyes and skin Do not stare at the operating light source The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified per...

Page 8: ...g It is recommend the use of appropriate clamps to fix the unit to the mounting surface ATTENTION A safety cable must be securely fixed to the unit s mounting bracket and to the support structure of t...

Page 9: ...of the second one In this way all the projectors are cascade connected If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX receptio...

Page 10: ...6 Projector 3 A013 A projector 6 A031 9 2 Selecting the DMX address 1 Press the UP DOWN key until you reach the required DMX address The numbers on the display will start to flash but the new DMX add...

Page 11: ...v 1 00 program At the end of the procedure the unit will reset For more information please refer to an authorised Thomann service centre 11 DISPLAY FUNCTIONS The TEATRO LED SPOT 100 display panel show...

Page 12: ...value Hz in order to reduce flickering in the process of your camera recordings Default 610 Hz Allows to increase the LED s current from 1470mA to 2100mA Default ON Automatic mode without DMX controll...

Page 13: ...table by user as on DMX channel 1 SHUTTER Default 15 Zoom excursion from min to max as on DMX channel 5 ZOOM Default 128 Black out Zoom motor startup reset enabled Default ON Zoom motor startup reset...

Page 14: ...128 Esc from Manual mode When Manual mode is active unit switch OFF ON cycle will maintain Manual Mode selection In Manual mode the DMX signal is ignored 13 ERROR MESSAGES ERROR SHOWED ON DISPLAY APP...

Page 15: ...immer from min to max 4 FUNCTIONS staying on desired option for 5 seconds 0 14 No function 15 24 SMOOTH OFF 25 26 SMOOTH 1 25 ms 27 28 SMOOTH 2 50 ms 29 30 SMOOTH 3 75 ms 31 32 SMOOTH 4 100 ms DEFAULT...

Page 16: ...REQUENCY 14000 Hz 129 OUTPUT FREQUENCY 15000 Hz 130 OUTPUT FREQUENCY 16000 Hz 131 OUTPUT FREQUENCY 17000 Hz 132 OUTPUT FREQUENCY 18000 Hz 133 OUTPUT FREQUENCY 19000 Hz 134 OUTPUT FREQUENCY 20000 Hz 13...

Page 17: ...Linear zoom from narrow to wide 6 RESET 0 15 No function 16 255 Zoom reset after 3 sec 2 CHANNELS MODE 1 DIMMER 2 ZOOM Ch Name DMX levels 1 DIMMER 0 255 Proportional dimmer from min to max 2 ZOOM 0 2...

Page 18: ...18 NOTES...

Page 19: ...19 NOTES...

Page 20: ...20 Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach info thomann de www thomann de 0517I324...