S T U D I O P A R P L A T I N U M 1 8 x 4 R G B + W W
10. MASTER ON/OFF
Set up master single send out ON/OFF
11. COOL MODE
1. STUDIO :
SETUPDIM 000%-080%
,
When the temperature is low 50
℃
,the fan will stop;but if
the temperature is over 50
℃
,the fan will circumvolve in slow speed; when the
temperature is over 70
℃
,DIM will drop to 60%.
2. REGULATED:
SETUPDIM 000%-100%,when the temperature is low 45
℃
,the fan will stop; when the
temperature is over 45
℃
and low 55
℃
, the fan will circumvolve in slow speed; when
the temperature is over 55
℃
, the fan will circumvolve in fast speed; when the
temperature is over 60
℃
,DIM will drop 2% with temperature raising 2
℃
.
3. POWER :
SETUPDIM 000%-100%,the fan will circumove in fast speed;when the temperature is over
70
℃
,DIM will drop to 60%.
8 / 8