background image

 

 

4 / 16 

L E D   A C C U   P A R  

 

Important:  

Damages caused by the disregard of this user manual are not subject to 

warranty. The dealer will not accept liability for any resulting defects or problems. 

Make sure the electrical connection is carried out by qualified personnel. All electrical 

and mechanical connections have to be carried out according to the European safety 

standards. 

 

 

1.2 Overhead Rigging 

 

This Item must be built in a way that it can hold 10 times more of its weight for 1 hour without 
causing any damages. 
The installation must be secured with a secondary safety attachment. The safety attachment 
has to be constructed in a way that no part of the installation can fall down 
When rigging, de-rigging or servicing the fixture staying in the area below the installation 
place, on bridges, under high working places and other endangered areas is forbidden. 
Before taking the device in operation, the installation must be approved by an expert. 
The operator has to make sure that safety-relating and machine-technical installations are 
approved by a skilled person once a year. 
 
 
 
Procedure: 
 
The Device must be installed outside areas where persons may walk by or be seated. 
 
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including 
(but not limited to) calculating working load limits, installation material being used, and 
periodic safety inspection of all installation material and the projector. If you lack these 
qualifications, do not attempt the installation yourself, but instead use a professional 
structural rigger. Improper installation can result in bodily injury and/or damage to property. 
 
Use only professional trussing systems if the Item shall be lowered from the ceiling or high 
joists. Never let the Device swing freely in a room. 
 
 
Caution: Overhead Items may cause serious injuries when crashing down!! If there is 
concern about the safety then DO NOT INSTALL the Device!!!! 
 

DANGER OF FIRE! 

When installing the device, make sure there is no highly-inflammable Material (decoration 
articles, etc.) within a distance of min. 0.5 m.

 

 
 
Mount the projector with the mounting-bracket to your trussing system using an appropriate 
clamp. 
For overhead use, always install a safety-rope that can hold at least 12 times the weight of 
the fixture. You must only use safety-ropes with quick links with screw cap. Pull the safety-
rope through the hole in the mounting-bracket and over the trussing system or a safe fixation 
spot. Insert the end in the quick link and tighten the safety screw. 
The maximum drop distance must never exceed 20 cm. 
 

Summary of Contents for LED Accu PAR 64 Floor RGB+W

Page 1: ...US ER MANUA L LED Accu PAR 64 Floor RGB W...

Page 2: ...s 5 2 1 DMX address 6 2 2 battery status 6 2 3 Set up for LED power mode 6 2 4 Manual colourselection 6 2 5 SET UP DISP ON or OFF 7 2 6 DMX Blackout Freeze 7 2 7 SET UP WIRELESS DMX 7 2 7 1 11 Reset t...

Page 3: ...he set in a location with high humidity or lots of dust Containers with water should not be placed on the set Keep away from sources of hum and noise Such as transformer motor tuner TV set and amplifi...

Page 4: ...seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all ins...

Page 5: ...a year 1 Make sure before installing that all screws are tightly connected and not corroded 2 There must be no deformations on the housings fixations and installations spots 3 No damages must be showe...

Page 6: ...choose the normal mode the dimmer works up to 80 When you choose the longlife mode the dimmer works up to 60 2 4 Manual colourselection Sets the maximum intensity of the color red from 0 100 This set...

Page 7: ...ax output in manual or DMX mode and the built in programs from 0 100 2 5 SET UP DISP ON or OFF white adjustment 2 6 DMX Blackout Freeze 2 7 SET UP WIRELESS DMX That s how you can turn on the wireless...

Page 8: ...ontrol if the Par is acting as a master or whether it should not send signals 14 Key Lock Here you can set up if the Par shall lock the buttons OFF means the buttons are not locked at any time 30s mea...

Page 9: ...t setting 3 DMX Control DMX Mode display flashes when no DMX signal is present Connect the signal output from your DMX controller with the XLR in jack on the Par On XLR out you can connect more DMX eq...

Page 10: ...MER 1 100 OUTPUT 2 0 255 GREEN 0 OFF 1 255 DIMMER 1 100 OUTPUT 3 0 255 BLUE 0 OFF 1 255 DIMMER 1 100 OUTPUT 4 0 255 WHITE 0 OFF 1 255 DIMMER 1 100 OUTPUT DMX MODE 5 channel value function 1 0 255 RED...

Page 11: ...1 255 DIMMER 1 100 OUTPUT 5 0 255 STROBE 0 15 OFF 16 255 1Hz 12Hz 6 0 255 MASTER 0 OFF 1 255 DIMMER 1 100 OUTPUT 7 0 255 0 31 Inaktiv special functions 32 63 automatic dimming 64 95 up automatic dimm...

Page 12: ...OUTPUT 5 0 255 STROBE 0 15 OFF 16 255 1Hz 12Hz 6 0 255 MASTER 0 OFF 1 255 DIMMER 1 100 OUTPUT 7 0 255 0 31 Inaktiv special functions 32 63 automatic dimming 64 95 up automatic dimming 96 127 down aut...

Page 13: ...s 004 Color transition 8 colors 005 strobe program 4 colors 006 Color change sequence 2 4 colors 007 Color change sequence 2 8 colors 008 Color transition 8 colors Speed mode value function 000 031 00...

Page 14: ...f WDMX off LED flashes quickly WDMX is connected LED flashes slowly no DMX signal is present LED is enduring on WDMX is connected and ready for usage 2 Power LED Shows the status of the battery LED is...

Page 15: ...pply Power consumption max 65W 7 1kg weight Size 274 x 285 x 377 5mm LxWxH DMX input 3pin XLR male socke WDMX Receiver DMX output 3pin XLR female socket WDMX Receiver DMX pinout Pin 1 Schirm Pin 2 Pin...

Page 16: ...16 16 L E D A C C U P A R Importer B K Braun GmbH Industriestra e 1 D 76307 Karlsbad Ittersbach www bkbraun com info bkbraun com...

Reviews: