background image

5

[DMX OUT]

DMX output, designed as 3-pin XLR panel socket (IP65)

6 Pressure compensation element

7

[POWER OUT]

Lockable chassis socket (Power Twist TR1 IP65) for the power supply of another device

8

[POWER IN]

Lockable chassis socket (Power Twist TR1 IP65) for the power supply of the device

Connections and controls

 

26

2bright Pint FC150 IP

LED spotlight

Summary of Contents for 2bright Pint FC150 IP

Page 1: ...2bright Pint FC150 IP LED spotlight User manual ...

Page 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Straße 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 02 07 2020 ID 481586 ...

Page 3: ...2 Safety instructions 11 3 Features 16 4 Installation 18 5 Starting up 22 6 Connections and controls 24 7 Operating 27 7 1 Starting the device 27 7 2 Operating on the unit 27 7 3 Menu overview 52 7 4 Functions in 1 channel DMX mode 53 7 5 Functions in 2 channel DMX mode 53 Table of contents 2bright Pint FC150 IP 3 LED spotlight ...

Page 4: ...e 54 7 8 Functions in 8 channel DMX mode 56 7 9 Functions in 11 channel DMX mode 58 8 Technical specifications 64 9 Plug and connection assignment 67 10 Troubleshooting 68 11 Cleaning 70 12 Protecting the environment 71 Table of contents 4 2bright Pint FC150 IP LED spotlight ...

Page 5: ...lable to all persons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous development We there fore reserve the right to make changes without notice Please refer to the latest version of the user manual which is ready for download under www thomann de General information 2bright Pint...

Page 6: ...e the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For personal consultation please contact our technical hotline Service If you have any problems with the device the customer service will gladly assist you General information 6 2bright Pint F...

Page 7: ...are brackets and italics Examples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks and italics Examples 24ch OFF Text inputs that are carried out on the device are indicated by typewriter font Example 2323 Letterings Displays Text input General information 2bright Pint FC150 IP 7 LED spotlight ...

Page 8: ... arrow Example 1 Switch on the device 2 Press Auto ð Automatic operation is started 3 Switch off the device 1 3 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this manual Instructions General information 8 2bright Pint FC150 IP LED spotlight ...

Page 9: ...and signal word indicates a pos sible dangerous situation that can result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environmental damage if it is not avoided Warning signs Type of danger Warning high voltage Warning hot surface General information 2bright Pint FC150 IP ...

Page 10: ...Warning signs Type of danger Warning dangerous optical radiation Warning suspended load Warning danger zone General information 10 2bright Pint FC150 IP LED spotlight ...

Page 11: ...rty damage No liability will be assumed for damages resulting from improper use This device may be used only by persons with sufficient physical sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety Extend the life of the device by regular bre...

Page 12: ...ke from the unit They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by short circuit Always use proper ready made insulated mains cabling power cord Do not modify the mains cable Failure to do so could result in electric shock death or fire If in doubt seek advice from a registered electrician Safety Safety instructions 12 2bri...

Page 13: ... present Never remove any covers There are no user serviceable parts inside Do not use the device if covers protectors or optical components are missing or damaged WARNING Eye damage caused by high light intensity Never look directly into the light source Safety instructions 2bright Pint FC150 IP 13 LED spotlight ...

Page 14: ...he surface of the device can become very hot during operation Do not touch the device with bare hands during operation and after switching off wait for at least 15 minutes NOTICE Risk of fire Do not block areas of ventilation Do not install the device near any direct heat source Keep the device away from naked flames Safety instructions 14 2bright Pint FC150 IP LED spotlight ...

Page 15: ... AC outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms occur and when it is unused for long periods of time to reduce the risk of electric shock or fire Safety instructions 2bright Pint FC150 IP 15 LED spotlight ...

Page 16: ...0 to 10 000 Hz n Fan control with Silent mode n Double bracket with omega bracket n Protection class IP65 Equipment with protection class IP65 are dust tight and completely protected against contact first code number They are also protected against splash water from any angle second code digit That is why this equipment can also be used outdoors Event technology equipment is generally only designe...

Page 17: ...t must be checked regularly to ensure a fault free operation In cases of doubt consult a specialist workshop in due time For technological reasons the light output of LEDs decreases over their lifetime This effect increases with higher operating temperature You can extend the service life of the illuminants by providing adequate ventilation and operating the LEDs with the lowest possible brightnes...

Page 18: ... or storage use the original packaging or your own packaging material suitable for transport or storage respectively WARNING Risk of injury caused by falling objects Make sure that the installation complies with the standards and rules that apply in your country Always secure the device with a secondary safety attachment such as a safety cable or a safety chain Installation 18 2bright Pint FC150 I...

Page 19: ...n the chapter Tech nical Specifications of the User Manual NOTICE Use of stands When mounting the device onto a stand ensure that the stand is in a safe and stable position and that the weight of the device does not exceed the maximum permissible load capacity of the stand Installation 2bright Pint FC150 IP 19 LED spotlight ...

Page 20: ...nnect the DMX input or output to audio devices such as mixers or ampli fiers NOTICE Possible damage due to moisture Moisture entering into open connectors plugs and couplers of DMX or power cords can cause short circuits Close unused connectors with end caps intended for this purpose www thomann de Installation 20 2bright Pint FC150 IP LED spotlight ...

Page 21: ... truss Use the openings of the bracket provided for mounting Always work from a stable platform whenever installing moving or servicing the unit In doing so the area underneath the unit must be cordoned off Please note that this device must not be connected to a dimmer Mounting options Installation 2bright Pint FC150 IP 21 LED spotlight ...

Page 22: ...e all connections while the device is off Use the shortest possible high quality cables for all connections Take care when running the cables to prevent tripping hazards Starting up 22 2bright Pint FC150 IP LED spotlight ...

Page 23: ...ice Connect the output of the first DMX device to the input of the second one and so on to form a daisy chain Always ensure that the output of the last DMX device in the daisy chain is terminated with a resistor 110 Ω W Connections in DMX mode Starting up 2bright Pint FC150 IP 23 LED spotlight ...

Page 24: ...6 Connections and controls Connections and controls 24 2bright Pint FC150 IP LED spotlight ...

Page 25: ...d MENU Activates the main menu toggles between the menu levels or closes a submenu DOWN Decreases the displayed value by one UP Increases the displayed value by one ENTER Opens a submenu or confirms a value 4 Bracket for floor placement or hanging Connections and controls 2bright Pint FC150 IP 25 LED spotlight ...

Page 26: ... compensation element 7 POWER OUT Lockable chassis socket Power Twist TR1 IP65 for the power supply of another device 8 POWER IN Lockable chassis socket Power Twist TR1 IP65 for the power supply of the device Connections and controls 26 2bright Pint FC150 IP LED spotlight ...

Page 27: ...ENU to activate the main menu 2 Press again MENU or UP or DOWN to call up further menu items 3 To activate the respectively shown menu item press ENTER 4 Press UP or DOWN to change the respectively indicated value 5 Press ENTER to apply the displayed value 6 To exit a menu item without making changes press MENU Navigating in the menu Operating 2bright Pint FC150 IP 27 LED spotlight ...

Page 28: ...All set values are retained even when you switch the device off and disconnect it from the mains Operating 28 2bright Pint FC150 IP LED spotlight ...

Page 29: ...s setting is only relevant when the device is controlled via DMX Make sure that this number matches the configuration of your DMX controller The following table shows the highest pos sible DMX address for the various DMX modes Mode Display Highest possible DMX address 1 channel 1CH 512 2 channel 2CH 511 4 channel 4CH 509 6 channel 6CH 507 Setting the DMX address Operating 2bright Pint FC150 IP 29 ...

Page 30: ...X Mode Confirm with ENTER 2 Use UP or DOWN to select the desired DMX mode 1 2 4 6 8 or 11 channels Depending on the selected mode the display shows 1CH 2CH 4CH 6CH 8CH or 11CH 3 Press ENTER to accept the selection This setting is only relevant when the device is controlled via DMX Setting the DMX mode Operating 30 2bright Pint FC150 IP LED spotlight ...

Page 31: ... or DOWN to select the desired automatic show display shows Program 1 Program 17 In submenu Program 17 programs 1 to 16 are played in random order Confirm with ENTER 4 Press UP or DOWN to select the desired submenu or the desired value The following sub menus are available Menu level 4 Menu level 5 Function Dimmer 000 255 Dimmer intensity Speed 000 255 Running speed from slow to fast 5 Press ENTER...

Page 32: ...splay shows Color1 Color46 or turn off the colour display shows Color Off Confirm with ENTER The following colour macros are available Colour macro Colour mixture R G B W Colour macro Colour mixture R G B W 1 255 0 0 0 24 50 0 255 0 2 255 15 0 0 25 95 0 255 0 3 255 35 0 0 26 130 0 255 0 4 255 70 0 0 27 190 0 255 0 5 255 125 0 0 28 225 0 255 0 6 255 170 0 0 29 255 0 255 0 Setting colour macro Opera...

Page 33: ... 9 200 255 0 0 32 255 0 95 0 10 160 255 0 0 33 255 0 70 0 11 110 255 0 0 34 0 0 40 0 12 70 255 0 0 35 255 0 20 0 13 0 255 0 0 36 255 0 7 0 14 0 255 10 0 37 0 0 0 255 15 0 255 25 0 38 255 0 0 255 16 0 255 45 0 39 125 0 0 255 17 0 255 70 0 40 0 255 0 255 18 0 255 120 0 41 0 120 0 255 Operating 2bright Pint FC150 IP 33 LED spotlight ...

Page 34: ... 180 255 0 43 0 0 100 255 21 0 70 255 0 44 0 0 50 255 22 0 0 255 0 45 198 145 15 0 23 20 0 255 0 46 198 145 17 255 4 Press UP or DOWN to select the desired value for the intensity of the colour macro display shows 006 255 5 Press ENTER to accept the selection Operating 34 2bright Pint FC150 IP LED spotlight ...

Page 35: ...lour that you can to adjust individually Confirm with ENTER 4 Press UP or DOWN to select the desired submenu or the desired value The following sub menus are available Menu level 3 Menu level 4 Function Dimmer 000 255 Dimmer intensity Strobe 0 30Hz Strobe effect from 0 to 30 Hz Red 000 255 Red Green 000 255 Green Blue 000 255 Blue White 000 255 White Setting constant colour Operating 2bright Pint ...

Page 36: ...then UP or DOWN repeatedly until the display shows Settings Confirm with ENTER 2 Press UP or DOWN repeatedly until the display shows Display Reverse Confirm with ENTER 3 Use UP or DOWN to select either On display rotated by 180 or Off display not rotated 4 Press ENTER to accept the selection Rotating the Display Operating 36 2bright Pint FC150 IP LED spotlight ...

Page 37: ...repeatedly until the display shows Display Backlight Confirm with ENTER 3 Use UP or DOWN to choose between On display permanently on and Off display turns off after a few seconds in case of inactivity 4 Press ENTER to accept the selection Setting display illumination Operating 2bright Pint FC150 IP 37 LED spotlight ...

Page 38: ...anualMode to make the setting to be used when the DMX controller fails The following sub menus are available Menu level 3 Function Hold Last The last effect is being held Blackout The spotlight is turned off ProgamMix The automatic preprogrammed shows are played Manual The device is switched to manual operation 4 Press ENTER to accept the selection Setting the behaviour on DMX control failure Oper...

Page 39: ...llowing sub menus are available Menu level 3 Function Linear without fade time Rise time 0 ms fall time 0 ms Fade time 1 s Rise time 0 ms fall time 0 ms Stage without fade time Rise time 780 ms fall time 1100 ms Fade time 1 s Rise time 1540 ms fall time 1660 ms TV without fade time Rise time 1180 ms fall time 1520 ms Fade time 1 s Rise time 1860 ms fall time 1940 ms Setting the dimmer curve Operat...

Page 40: ...ll time 2120 ms Theatre without fade time Rise time 1580 ms fall time 1940 ms Fade time 1 s Rise time 2230 ms fall time 2280 ms Stage2 without fade time Rise time 0 ms fall time 1100 ms Fade time 1 s Rise time 0 ms fall time 1660 ms 4 Press ENTER to accept the selection Operating 40 2bright Pint FC150 IP LED spotlight ...

Page 41: ...ings Confirm with ENTER 2 Press UP or DOWN repeatedly until the display shows Dimmer Speed Confirm with ENTER 3 Use UP or DOWN to select a dimmer speed between 0 1 0 9 seconds and 1 10 sec onds display shows 0 1 0 9s 1 10s 4 Press ENTER to accept the selection Setting the dimmer speed Operating 2bright Pint FC150 IP 41 LED spotlight ...

Page 42: ... the display shows Auto Lock Confirm with ENTER 3 Use UP or DOWN to choose between On keylock on and Off keylock off 4 Press ENTER to accept the selection Simultaneously press UP and DOWN for 5 seconds if you want to activate the input while the keylock is activated Enabling keylock Operating 42 2bright Pint FC150 IP LED spotlight ...

Page 43: ...ired fan mode The following sub menus are available Menu level 3 Function Smart The fan speed is controlled automatically by the device temperature Silent The fan is off silent mode The device tempera ture is controlled by reducing the power con sumption to a maximum of 70 W Max The fan runs at maximum speed 4 Press ENTER to accept the selection Setting fan mode Operating 2bright Pint FC150 IP 43 ...

Page 44: ...e Confirm with ENTER 3 Use UP or DOWN to select the value for the LED repetition rate The following table shows the available options Menu level 3 Function 900Hz PWM 900 Hz 1000Hz PWM 1 5 kHz 1100Hz PWM 1 1 kHz 1200Hz PWM 1 2 kHz 1300Hz PWM 1 3 kHz 1400Hz PWM 1 4 kHz 1500Hz PWM 1 5 kHz LED repetition rate PWM Operating 44 2bright Pint FC150 IP LED spotlight ...

Page 45: ...Menu level 3 Function 2500Hz PWM 2 5 kHz 4000Hz PWM 4 kHz 5000Hz PWM 5 kHz 6000Hz PWM 6 kHz 10000Hz PWM 10 kHz 4 Press ENTER to accept the selection Operating 2bright Pint FC150 IP 45 LED spotlight ...

Page 46: ... display shows Service Confirm with ENTER 3 Press UP or DOWN repeatedly until the display shows Reset Confirm with ENTER ð You are prompted to enter a password 4 Enter the password 11 5 Press ENTER ð The device is reset to factory default settings Resetting the device to factory defaults Operating 46 2bright Pint FC150 IP LED spotlight ...

Page 47: ...ter the password 50 Confirm with ENTER 4 Use UP or DOWN to select the value for the colour calibration The following table shows the available options Menu level 4 Menu level 5 Function Red 000 255 Calibration of red Green 000 255 Calibration of green Blue 000 255 Calibration of blue White 000 255 Calibration of white 5 Press ENTER to accept the selection Calibrating colours Operating 2bright Pint...

Page 48: ...re ð The current firmware version is displayed 1 Press MENU and then UP or DOWN repeatedly until the display shows System Info Confirm with ENTER 2 Press UP or DOWN until the display shows LED On Time ð The operation hours of the LED are displayed Firmware version display LED operating hours display Operating 48 2bright Pint FC150 IP LED spotlight ...

Page 49: ...rs ð The operation hours of the device are displayed 1 Press MENU and then UP or DOWN repeatedly until the display shows System Info Confirm with ENTER 2 Press UP or DOWN until the display shows Temperature ð The current device temperature is displayed Device operating hours display Show device temperature Operating 2bright Pint FC150 IP 49 LED spotlight ...

Page 50: ...epeatedly until the display shows System Info Confirm with ENTER 2 Press UP or DOWN until the display shows RDM ð The display shows the UID code Parameter ID Recognition command Sent Command Received Command DISC_UNIQUE_BRANCH DISC_MUTE DISC_UN_MUTE DEVICE_INFO SOFTWARE_VERSION_LABEL DMX_START_ADDRESS RDM function Operating 50 2bright Pint FC150 IP LED spotlight ...

Page 51: ...ommand Sent Command Received Command IDENTIFY_DEVICE SUPPORTED_PARAMETERS SENSOR_DEFINITION SENSOR_VALUE DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION RESET_DEVICE FACTORY_DEFAULTS Operating 2bright Pint FC150 IP 51 LED spotlight ...

Page 52: ...7 3 Menu overview Operating 52 2bright Pint FC150 IP LED spotlight ...

Page 53: ...e Function 1 Blinder mode 7 5 Functions in 2 channel DMX mode Channel Value Function 1 000 255 Dimmer intensity from dark 0 to bright 255 2 Colour macros 000 007 No function 008 255 Colour macros 1 46 Operating 2bright Pint FC150 IP 53 LED spotlight ...

Page 54: ...ensity green 0 100 3 000 255 Intensity blue 0 100 4 000 255 Intensity white 0 100 7 7 Functions in 6 channel DMX mode Channel Value Function 1 000 255 Dimmer intensity from dark 0 to bright 255 2 000 255 Intensity red 0 100 3 000 255 Intensity green 0 100 Operating 54 2bright Pint FC150 IP LED spotlight ...

Page 55: ...roboscope 000 010 LED on 011 020 LED off 021 030 Singly strobe pulse 031 090 Strobe effect increasing speed 091 100 LED on 101 170 Strobe pulses short burst with pause 171 180 LED on 181 240 Random strobe effect increasing speed 241 255 LED on Operating 2bright Pint FC150 IP 55 LED spotlight ...

Page 56: ... 255 Fine adjustment dimmer 0 100 3 000 255 Intensity red 0 100 4 000 255 Intensity green 0 100 5 000 255 Intensity blue 0 100 6 000 255 Intensity white 0 100 7 Stroboscope 000 010 LED on 011 020 LED off 021 030 Single strobe pulse 031 090 Strobe effect increasing speed Operating 56 2bright Pint FC150 IP LED spotlight ...

Page 57: ...lue Function 091 100 LED on 101 170 Strobe pulses short burst with pause 171 180 LED on 181 240 Random strobe effect increasing speed 241 255 LED on 8 Blinder mode Operating 2bright Pint FC150 IP 57 LED spotlight ...

Page 58: ... 255 Fine adjustment dimmer 0 100 3 000 255 Intensity red 0 100 4 000 255 Intensity green 0 100 5 000 255 Intensity blue 0 100 6 000 255 Intensity white 0 100 7 Stroboscope 000 010 LED on 011 020 LED off 021 030 Single strobe pulse 031 090 Strobe effect increasing speed Operating 58 2bright Pint FC150 IP LED spotlight ...

Page 59: ... 181 240 Random strobe effect increasing speed 241 255 LED on 8 Blinder mode 9 Colour macros 000 007 No function 008 255 Colour macros 1 46 10 Dimmer curves 000 010 Default setting of the device 011 020 Dimmer curve Linear 021 040 Dimmer curve Stage Operating 2bright Pint FC150 IP 59 LED spotlight ...

Page 60: ...ve Architectural 081 100 Dimmer curve Theatre 101 120 Dimmer curve Stage2 121 Delay 0 1 s 122 Delay 0 2 s 123 Delay 0 3 s 124 Delay 0 4 s 125 Delay 0 5 s 126 Delay 0 6 s 127 Delay 0 7 s 128 Delay 0 8 s 129 Delay 0 9 s Operating 60 2bright Pint FC150 IP LED spotlight ...

Page 61: ...s 132 Delay 2 0 s 133 Delay 3 0 s 134 Delay 4 0 s 135 Delay 5 0 s 136 Delay 6 0 s 137 Delay 7 0 s 138 Delay 8 0 s 139 Delay 9 0 s 140 Delay 10 s 141 255 Default setting of the device 11 LED repetition rate Operating 2bright Pint FC150 IP 61 LED spotlight ...

Page 62: ...n 011 020 900 Hz 021 030 1000 Hz 031 040 1100 Hz 041 050 1200 Hz 051 060 1300 Hz 061 070 1400 Hz 071 080 1500 Hz 081 090 2500 Hz 091 100 4000 Hz 101 110 5000 Hz 111 120 6000 Hz 121 130 10 000 Hz Operating 62 2bright Pint FC150 IP LED spotlight ...

Page 63: ...n 131 140 Default setting of the device Fan mode 141 150 Fan mode Silent 151 160 Fan mode Smart 161 170 Fan mode Max 171 180 Default setting of the device 181 255 No function Operating 2bright Pint FC150 IP 63 LED spotlight ...

Page 64: ...0 Colour temperature 7500 K Repetition rate 900 Hz 10 kHz Control DMX RDM Buttons and display Number of DMX channels 1 2 4 6 8 11 Input connections Voltage supply Lockable input socket Power Twist TR1 IP65 DMX control XLR panel plug IP65 3 pin Technical specifications 64 2bright Pint FC150 IP LED spotlight ...

Page 65: ...ing supply voltage 100 240 V 50 60 Hz Protection class IP65 Mounting options hanging standing Dimensions W H D with bracket 234 mm 308 mm 237 5 mm Dimensions W H D w o bracket 234 mm 150 mm 237 5 mm Weight 4 2 kg Ambient conditions Temperature range 5 C 45 C Relative humidity 50 non condensing Technical specifications 2bright Pint FC150 IP 65 LED spotlight ...

Page 66: ... cannon Number of LEDs 1 Colour mixture RBGW LED type x in 1 Floor housing Yes Fanless No Remote control Not possible Wireless DMX No Housing colour black Further information Technical specifications 66 2bright Pint FC150 IP LED spotlight ...

Page 67: ... the result of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show A three pole coupling in IP65 design is used as DMX output a three pole plug in IP65 design is used as DMX input The drawing below and the table show the pin assignment of a matching coupling Pin Assignment 1 Ground shielding 2 Signal inverted DMX cold 3 Signal DMX hot Introduc...

Page 68: ...s and do not use ordi nary microphone cables Never connect the DMX input or output to audio devices such as mixers or ampli fiers In the following we list a few common problems that may occur during operation We give you some suggestions for easy troubleshooting Troubleshooting 68 2bright Pint FC150 IP LED spotlight ...

Page 69: ...ttings and the DMX polarity 3 Try using another DMX controller 4 Check to see if the DMX cables run near or alongside to high voltage cables that may cause damage or interfer ence to DMX interface circuits If the procedures recommended above do not succeed please contact our Service Center You can find the contact information at www thomann de Troubleshooting 2bright Pint FC150 IP 69 LED spotlight...

Page 70: ...uency of cleaning depends on the operating environment wet smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device n Clean with a soft cloth using our lamp and lens cleaner item no 280122 n Always dry the parts carefully Optical lenses Cleaning 70 2bright Pint FC150 IP LED spotlight ...

Page 71: ...nd markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household waste Dispose of this device through an approved waste disposal firm or through your local waste facility When discarding the device comply with the rules and regulations that apply in your country If ...

Page 72: ...Notes 72 2bright Pint FC150 IP LED spotlight ...

Page 73: ...Notes 2bright Pint FC150 IP 73 LED spotlight ...

Page 74: ...Notes 74 2bright Pint FC150 IP LED spotlight ...

Page 75: ......

Page 76: ...Musikhaus Thomann Hans Thomann Straße 1 96138 Burgebrach Germany www thomann de ...

Reviews: