Hardware Specifications

Chassis

Size (L x W x H:)

Weight

Temperature

Humidity

ML

2.5

-60-35: 

350 x 350  x 200 mm (13.78 x 13.78 x 7.87

 

in.)

ML

2.5

-60-19:

190 x 190  x 120 mm (7.48 x 7.48 x 4.72

 

in.)

ML

2.5-

60-35: 3.5 kg (7.72 lb)

ML

2.5

-60-19: 2 kg (4.41 lb)

Operating: -

3

0 °C to 

55

 °C (-

22

 °F to 1

31

 °F)

 

Storage: -40 °C to 70 °C (-40 °F to 158 °F)

Operating: 10% to 90% (non-condensing)

Network Interfaces

Ports

WAN

 RJ-45 Port: 1000BASE-T, passive PoE

LAN

 RJ-45 Port: 1000BASE-T

60 GHz Radio

IEEE 802.11ad

5 GHz Radio

IEEE 802.11ac

Radio Frequencies

5150 ~ 5250 MHz (FCC)
5725 ~ 5850 MHz (FCC)
5745 ~ 5825 MHz (China)
5180 ~ 5320 MHz (ETSI)
5500 ~ 5700 MHz (ETSI)
58.32 ~ 64.80 GHz 

Power Supply

Passive PoE

24 VDC, maximum 1 A 

Power Consumption

15 W maximum

Regulatory Compliances

Radio

Emissions

Immunity

EN 300 328 V1.8.1:2012
EN 301 893 V1.7.1:2012
EN 301 489-1 V1.9.2 (2011-09)
EN 301 489-17 V2.2.1:2012

IC RSS-247 (5725 ~ 5850 MHz)

FCC Part 15E 15.407 (5.150GHz-5.250GHz, 
5.725-5.850GHz)

EN 55022 2010+AC:2011
EN 61000-3-2 2006+A1:2009+A2:2009

 

FCC 

Class B Part 15

EN 55024 : 2010
EN 61000-4-2 : 2009

Summary of Contents for MetroLinq2.5 ML2.5-60-35

Page 1: ...our location and select hardware accordingly Power Up Welcome to MetroLinq Interference Free Gigabit Wireless Ensure all four position locking bolts are tight before installing 1 Install the bracket o...

Page 2: ...l position Re tighten bolt 4 Loosen the vertical fine tune adjustment bolt 1 Use fine tune bolt A to optimize the vertical position Re tighten bolt 1 Initial alignment should be based on optical or vi...

Page 3: ...with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 48 cm between the radiator and your body Note The co...

Page 4: ...or network and service supply not for spectrum Norway Implemented This subsection does not apply for the geographical area within a radius of 20 km from the centre of Ny lesund Russian Federation None...

Page 5: ...adio LAN device sp a z kladn po iadavky a v etky pr slu n ustanovenia Smernice 1999 5 ES Slovenian Slovensko IgniteNet izjavlja da je ta radio LAN device v skladu z bistvenimi zahtevami in ostalimi re...

Page 6: ...PoE LAN RJ 45 Port 1000BASE T 60 GHz Radio IEEE 802 11ad 5 GHz Radio IEEE 802 11ac Radio Frequencies 5150 5250 MHz FCC 5725 5850 MHz FCC 5745 5825 MHz China 5180 5320 MHz ETSI 5500 5700 MHz ETSI 58 32...

Page 7: ...e following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to whic...

Page 8: ...t type are strictly prohibited for use with this device Le pr sent metteur radio IC 3857A ML2560 a t approuv par Industrie Canada pour fonctionner avec les types d antenne num r s ci dessous et ayant...

Page 9: ...ment This equipment should be installed and operated with minimum distance 69 cm between the radiator your body Cet quipement est conforme aux limites d exposition aux rayonnements IC tablies pour un...

Reviews: