![IGM LAGUNA AFlux 12 Operating Instructions Manual Download Page 5](http://html1.mh-extra.com/html/igm/laguna-aflux-12/laguna-aflux-12_operating-instructions-manual_3930164005.webp)
-5-
www.igmtools.com
151-AFLUXIF
3 BAG FILTER
151-AFLUXOF
ELECTROSTATIC FILTER
4. Thread the eye-bolts into the four holes
where the screws were removed in STEP 2.
Be certain that the flange nuts are tightened
against the surface of the air cleaner.
When suspending the air cleaner from the
ceiling or other overhead support, use steel
s-hooks that are a minimum of 1 cm.
Thread all lag hooks at least 4 cm into the
supporting structural members.
5. Operation
The air cleaner may produce a slight odour
for the first few hours of operation due to the
protective coating which is applied to internal
components. This odour will dissipate and
should be disregarded. The 3 Speed Ambient
Air Cleaner with Electrostatic Filter can be
used in application where non-metallic dust
is a factor.
Onboard Control
To reduce the risk of fire or electric shock, do
not use this unit with any solid-state speed
control device.
TIMER: Displays the current timing setting
SPEED: Displays the current speed setting
Manual – ON/OFF SPEED: Toggles between
on, low speed, medium speed, high speed,
off.
Manual – TIMER: Toggles between 1/2h, 1h,
2h, 4h, off.
Remote Control
Timer: Toggles between 1/2h, 1h, 2h, 4h, off.
Speed: Toggles between low speed, medium
speed, high speed, off.
ON/OFF: Power
6. Maintenance
6.1. Changing an
d Cleaning Filters
When cleaned as directed, your electrostatic
air filter will give you many years of trouble-
free use. Failure to properly clean the filter
may lessen filter effectiveness, and as with
any air filter, it is possible for an excessive dirt
buildup to cause air flow resistance enough
to damage other ventilation components.
Depending on your specific situation the filter
should be cleaned every 4-6 weeks.
There is an “air flow” indicator located on the
left side of the unit. To check the filters, turn the
unit “ON”. If the indicator points to “green”, the
filters are clean.
6.2 Cleaning Procedure
1. Turn the unit “OFF”.
2. Remove the outer first stage filter by lifting
and pulling out on the bottom of the filter.
3. Rinse thoroughly to remove remaining dirt.
4. Drain excess water, let air dry, and reinstall.
5. Replace the filter, turn the unit “ON”, and
check the air flow indicator again.
6. If the air flow indicator points to “green”, the
inner filter is still usable. If the indicator points
to “red”, remove the outer filter, then remove
the inner filter by lifting and pulling out on
the bottom of the filter. DO NOT try to clean
the inner filter. It is disposable and must be
replaced.
7. After replacing the inner filter, reinstall the
outer filter.
NOTE:
The 3 bag filter is very durable. The
material is multiple layers synthetic microfiber.
The synthetic microfiber builds up in non-woven
layers to ensure multi-layers buildup and
eliminate fiber shedding.
This bag filter is not washable. Clean it
up by compressed air periodically or by
vacuum light brush (recommended once per
month).
Then you can repeat to use it till it is clogged
up by the dusts and the air flow is reduced
obviously.
Replacement 3 bag filters (151-AFLUXIF) are
available from www.igmtools.com.
7. Service
To order parts, call the store you purchased
it from.
7.1 Parts List
P-6142422021
REMOTE CONTROL
P-603065326002
POWER CORD
P-6011110107001016120
MOTOR
P-2SF-C80-021
FAN/IMPELLER
P-2043154
PCB CONTROL BOARD
P-6020604102
5A RELAY