IGM LAGUNA AFlux 12 Operating Instructions Manual Download Page 5

-5-

www.igmtools.com

151-AFLUXIF 

                                    

3 BAG FILTER

 

151-AFLUXOF 

       

ELECTROSTATIC FILTER

4. Thread the eye-bolts into the four holes 

where the screws were removed in STEP 2.

Be certain that the flange nuts are tightened 

against the surface of the air cleaner.

When suspending the air cleaner from the 

ceiling or other overhead support, use steel 

s-hooks that are a minimum of 1 cm.

Thread all lag hooks at least 4 cm into the 

supporting structural members.

 

5. Operation

The air cleaner may produce a slight odour 

for the first few hours of operation due to the 

protective coating which is applied to internal 

components. This odour will dissipate and 

should be disregarded. The 3 Speed Ambient 

Air Cleaner with Electrostatic Filter can be 

used in application where non-metallic dust 

is a factor.

Onboard Control

To reduce the risk of fire or electric shock, do 

not use this unit with any solid-state speed 

control device.

TIMER: Displays the current timing setting 

SPEED: Displays the current speed setting

Manual – ON/OFF SPEED: Toggles between 

on, low speed, medium speed, high speed, 

off.

Manual – TIMER: Toggles between 1/2h, 1h, 

2h, 4h, off.

 

Remote Control

 

Timer: Toggles between 1/2h, 1h, 2h, 4h, off.

Speed: Toggles between low speed, medium 

speed, high speed, off.

ON/OFF: Power

6. Maintenance

6.1. Changing an

d Cleaning Filters

When cleaned as directed, your electrostatic 

air filter will give you many years of trouble-

free use. Failure to properly clean the filter 

 

 

may lessen filter effectiveness, and as with 

any air filter, it is possible for an excessive dirt 

buildup to cause air flow resistance enough 

to damage other ventilation components. 

Depending on your specific situation the filter 

should be cleaned every 4-6 weeks.

There is an “air flow” indicator located on the 

left side of the unit. To check the filters, turn the 

unit “ON”. If the indicator points to “green”, the 

filters are clean.

6.2 Cleaning Procedure

1. Turn the unit “OFF”.

2. Remove the outer first stage filter by lifting 

and pulling out on the bottom of the filter. 

3. Rinse thoroughly to remove remaining dirt.

4. Drain excess water, let air dry, and reinstall.

5. Replace the filter, turn the unit “ON”, and 

check the air flow indicator again.

6. If the air flow indicator points to “green”, the 

inner filter is still usable. If the indicator points 

to “red”, remove the outer filter, then remove 

the inner filter by lifting and pulling out on 

the bottom of the filter. DO NOT try to clean 

the inner filter. It is disposable and must be 

replaced.

7. After replacing the inner filter, reinstall the 

outer filter.

NOTE:

 The 3 bag filter is very durable. The 

material is multiple layers synthetic microfiber. 

The synthetic microfiber builds up in non-woven 

layers to ensure multi-layers buildup and 

eliminate fiber shedding.

This bag filter is not washable. Clean it 

up by compressed air periodically or by 

vacuum light brush (recommended once per 

month).

Then you can repeat to use it till it is clogged 

up by the dusts and the air flow is reduced 

obviously.

Replacement 3 bag filters (151-AFLUXIF) are 

available from www.igmtools.com.

 

7. Service

 

To order parts, call the store you purchased 

it from.

7.1 Parts List

 

P-6142422021 

        

REMOTE CONTROL 

P-603065326002 

POWER CORD 

P-6011110107001016120 

               

MOTOR 

P-2SF-C80-021 

FAN/IMPELLER

 

 

P-2043154 

PCB CONTROL BOARD 

P-6020604102 

5A RELAY 

Reviews: