HEATING SYSTEM WITH BUFFER CAPACITY
This diagram provides a hydraulic diagram of the heating system, when the temperature
control of individual room circuits by actuators is provided in the object. It is recommended to install
a buffer tank for fixed capacity heat pumps when planning to regulate the temperature for individual
rooms. Otherwise, without installing the buffer tank, up to 30% of the heating circuit can be closed at
the same time. Variable capacity heat pumps do not require buffer capacity.
Each heat pump has the ability to connect to the Internet, so you can see the heat pump
settings and control the system remotely.
Čia:
- paduodamas termofikatas;
- gr
įžtantis termofikatas;
- i
šeinantis glikolis;
-
įeinantis glikolis.
Šildymo
kontūras
Karšto
vandens
boileris
Buferinė
talpa
Šilumos
siurblys
Lauko kontūras
Where:
Supply heating water
Return heating water
Outgoing glycol
Incoming glycol
Heat pump
Heating circuit
Hot
water
boiler
Outdoor circuit
Buffer
tank