en
21
User manual Luzon, Luzon Deep
www.igloo.pl
Remarks and indications
•
It is necessary to properly level the display cabinet, which will prevent loud operation of the device
andshall ensure proper water (condensate) outflow during defrosting.
•
After transporting the device, wait about 2 hours before its actuation.
•
The first filling of cooling space should be performed after its previous cooling to working tempera
-
ture. This principle should also be observed after longer pause in exploitation.
•
Do not block any ventilation holes, which would hamper circulation of the cooled air. It is also neces
-
sary to ensure proper airflow around the device (aggregate ventilation holes cannot be covered).
•
Ensure even load on shelves, do not exceed their maximal load and do not exceed maximal lo
-
ading.
•
Keep the condenser clean. Impurities may lead to overheating of the compressor and as a conse
-
quence may result in damage of the device, which is not covered by warranty.
•
Do not use electric devices inside grocery product storing chamber.
•
After closing the door of the device, it is not recommended to open it with force. Negative pressure
created inside the device is levelled within 1-2 minutes, which allows easy opening of the door.
•
Avoid unnecessary opening of doors and leaving them open for a longer period of time.
4.1. Temperature regulation
Service of “Igloo” and “Carel” thermostat (temperature regulators) is described in chapter 7 (p. 26 and 27)
The basic aim of a thermostat is to control the cooling aggregate to obtain the set temperature within the device and
maintain it within the determined temperature ranges. The producer enters all settings of temperature regulato
srequired for normal functioning of the device. Before primary actuation the user should control and possibly set the
required temperature inside the device on the control panel.
Digital display
– displays the current temperature inside the device.
It is forbidden to interfere with systemic parameters of the thermostat, as this can lead to serious
consequences, including the damage of the cooling device!
5. MAINTENANCE
5.1. Cleaning and maintenance
All maintenance services need to be performed after disconnecting the device from power supply!
Protect electric installation against any damage or water spillage
4. EXPLOITATION
Temperature of the cooled space and aggregate operating cycle may fluctuate. It depends on numerous factors,
such as amount and temperature of products placed in the device and temperature of the surroundings.
The device should be placed in a dry and well-ventilated place, ensuring proper air exchange (distance between the
wall and the device – min. 10 cm), out of sunlight, kept far from heat sources and devices enforcing air flow (ceiling
and portable ventilators, blow-in heaters). The device functions properly in a room, where temperature falls within
appropriate climatic class stated on the data plate. The operation of the device may worsen when it shall operate in
temperature lower or higher than the stated temperature range.