6.10 Info
Under "Info" you can safely display device information. It includes the following:
-
ECU firmware version (pneumatic unit)
-
HH firmware version (control unit)
-
Serial number
-
Last service
7. External start/stop button
The device has an external start/stop button connection. This can be used to start or stop the
braking process.
To prevent a braking process from being triggered both by the control unit and the external
start/stop button, the device has a cable connection detection feature. If the external start/stop
button is connected, the device blocks triggering via the control unit.
8. Alerts
The following alerts may appear on the display during operation:
-
Warning: Perform zero calibration of the pressure sensor
-
Beware: Pressure switch triggered!
-
Error: Timeout on receiving ECU
8.1 Alert: "Warning: Perform zero calibration of pressure sensor".
This alert appears if the last zero calibration was made more than 24 hours ago. The alert
serves exclusively as an indication and can be acknowledged with "OK" (2). If zero calibration
is not carried out within the next hour, the alert appears again. For safety reasons, this alert is
not displayed when a print is controlled (status: Run).