ifs VT5020 Installation/Operation Instructions Warranty Information Download Page 3

International Fiber Systems, Inc.

16 Commerce Road 

 Newtown, Connecticut 06470 USA 

 Tel: 203.426.1180 

 Fax: 203.426.3326

VT/VR5000 Rev: 1 07/11/98

POWER CONNECTION

(a)

 

Stand-alone Modules:

VT/VR5000 SERIES

12 VDC INPUT

PIN 1

+12 VC

PIN 2

GROUND

(b)  “–R3” Modules:

All “-R3” models receive power from the back plane of the R3 rack.  Insert the “-R3” unit into an

available R3 rack slot such that the female 3-pin connector on the back of the module engages the companion
male connector of the back plane.   The red power LED will glow when voltage is applied to the unit.

CAMERA CONNECTION

Attach 75-ohm coaxial cables (terminated with BNC connectors) from the video output connectors of four

separate cameras to the four "VIDEO IN" BNC connectors on the VT5000 series module.

MONITOR CONNECTION

Attach 75-ohm coaxial cables (terminated with BNC connectors) from the four "VIDEO OUT" BNC

connectors on the VR5000 series module to video input connectors of a monitor (or switcher).

FIBER OPTIC CONNECTION

Select a quality fiber optic cable containing either 62.5/125 µ fiber for multimode interfaces or 9/125 fiber

for single mode interfaces.  Attach a ST style fiber optic connector using the connector manufacturer's
recommended procedures.  Connect the fiber optic cable to the ST connector marked "OPTICAL OUT" on the
VT5000 series module to the ST connector marked “OPTICAL IN” on the VR5000 series module.

MOUNTING STAND-ALONE UNITS

Hold the VT5000 or VR5000 series module against the mounting surface and mark the locations of the

keyhole slots on the rear mounting brackets.  Install mounting screws into keyhole marks, allowing leeway
under the screw heads for the box to be mounted.  Mount the brackets over the screws, slide, and tighten.