Instruction manual for wall / ceiling mounted light fixture with
integrated motion sensor function ON-OFF.
Applicable for Ifö – TYPE 8263 and 8263/GX24.
20814 Not 1
Ifö Electric AB SE - 29522 Bromölla www.ifoelectric.com
Important to remember when installing fixtures:
•
The sensitivity of the sensor may cause it to register movement through thin walls and glass.
•
The fixture must be mounted on a stable foundation and not subject to vibrations.
•
Large metal surfaces, close to the sensor may cause detection.
•
The ventilation exhaust and air draft may cause unwanted detection.
•
Fixtures with sensor should not be place within each other's detection area.
Function:
•
The sensor detects movements and shuts the relay. A light is lit. After the last detection, the light lights up according to the time
set on the sensor.
•
The high-frequency radiation emitted from the sensor is less than 10 mW; i.e. 1 % of the radiation effect of a mobile telephone.
Installation:
1.
Make sure that the power is turned off before installation.
2.
Remove the wires through the rubber sleeve.
3.
Mount the fixture using an optional CC-measurement. CC-70 can be tapped out with a screwdriver.
4.
Connect the wires to the connection terminal.
5.
Set in the source of light, according to the silver label on the reflector.
Max. 20 W low-energy (CFL) for E27 and max. 18 W T/E
for GX24q-2.
6.
Place silicone washers over the threading of the shade and fasten the shade onto the fixture.
7.
To for external cable attachments there are 3 cut-off walls used by carefully tapping on the outside inwards with a screwdriver.
Do not use nippers.
Setting the sensor
Sensitivity
Power-off delay
Lux threshold
Sensitivity to ceiling mounting (m)
S
en
sitiv
ity
to
w
all m
o
u
n
tin
g
(
m
)