background image

2

1  Preliminary note

1.1  Symbols used

Instructions

>

Reaction, result

[…] Designation of keys, buttons or indications

Cross-reference

Important note 

Non-compliance may result in malfunction or interference.

Information 

Supplementary note.

2  Safety instructions

•  Read this document before setting up the product and keep it during the entire 

service life.

•  The product must be suitable for the corresponding applications and 

environmental conditions without any restrictions.

•  Only use the product for its intended purpose 

(→ 3 Functions and features)

.

•  If the operating instructions or the technical data are not adhered to, personal 

injury and/or damage to property may occur. 

•  The manufacturer assumes no liability or warranty for any consequences 

caused by tampering with the product or incorrect use by the operator.

•  Installation, electrical connection, set-up, operation and maintenance of the 

product must be carried out by qualified personnel authorised by the machine 

operator.

•  Protect units and cables against damage.

3  Functions and features

Ultrasonic sensor for monitoring levels and detecting objects.

Summary of Contents for UIT509

Page 1: ...Operating instructions Ultrasonic diffuse reflection sensor without IO Link UIT509 UIT512 UIT515 11487721 00 08 2018 UK UK ...

Page 2: ...ut any restrictions Only use the product for its intended purpose 3 Functions and features If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up ope...

Page 3: ...eet No object detection in the dead zone For units with metal housing according to UL 508 Observe a minimum distance of 12 7 mm between the sensor and non insulated live parts For further information please refer to www ifm com General information about installation and operation 5 Electrical connection Disconnect power Connect unit depending on the type selected BK black BN brown BU blue WH white...

Page 4: ...Press the teach button for 1 s Yellow status LEDs 1 2 flash 2 5 Hz P1 setting is completed Position the object in P2 Fig 1 or 2 Press the teach button for 1 s Yellow status LEDs 1 2 flash briefly 4 Hz P2 setting is completed 6 1 3 Invert output response Press the teach button for 6 s Yellow status LEDs 1 2 flash 10 Hz Yellow status LEDs 1 2 flash briefly 4 Hz Output function is inverted 6 1 4 Rest...

Page 5: ...s Complementary switching outputs 1 1 B P2 P1 1 0 0 3 4 2 B P1 P2 2 1 0 1 0 1 3 4 Inverted switching outputs Inverted switching outputs 1 1 B P2 P1 1 0 0 2 3 4 1 1 B P1 P2 1 0 0 2 3 4 1 output response 2 distance to the object 3 OUT1 switching output 4 OUT2 switching output B blind zone P taught position T teach button Technical data and further information at www ifm com ...

Reviews: