Special conditions for safe operation
• The sensors are designed for a low risk of mechanical damage. The sensor housing and
the cable must be effectively protected against mechanical stress and damage by means
of appropriate measures.
• The cable must be firmly laid. During mounting, dismounting and operation of the sensor it
must be ensured that no tensile or pressure loads above F = 20 Newton are applied on the
sensor housing from the cable or vice versa.
• Units or sensors without direct earthing must be installed in an earthed metallic system
ensuring a permanent electrical connection, and so indirectly earthed.
Maintenance / Repair
The unit must not be modified nor can it be repaired. In case of a fault please contact the
manufacturer.
The data sheets and the EC declaration of conformity are available from the manufacturer on
request.