Air gap sensor
SDP110
27
u
Use the system commands [SP1 teach] or [SP2 teach] to set the parameters for limit values of the
unit.
More detailed information can be found in the IODD at
10.2.5 User settings (optional)
10.2.5.1 Standard display
u
Select the DIS menu.
u
Select [diS.L] and set the process value display:
•
L1 = current process value for distance
•
L2.Flow = current process value for distance and flow
•
L2.Pres = current process value for distance and pressure
•
L3 = current process value for distance, flow and pressure
u
Select [diS.U] and set the refresh rate of the display:
•
d1: High
•
d2: Medium
•
d3: Low
u
Select[diS.R] and set the orientation of the display:
•
0°, 90°, 180°, 270°
u
Select [diS.B] and set the brightness of the display:
•
25 %, 50 %, 75 %, 100 %.
•
OFF: The process value display is switched off in the operating mode (energy-saving mode).
Error messages are displayed even if the display is deactivated. Display activation by pressing
any key.
10.2.5.2 Standard unit of measurement
Set the standard unit of measurement before all other parameter settings (
25).
10.2.5.3 Display colour setting
u
Select the COLR menu.
u
Select [coL.x] and set the colour of the characters of the process value display:
bk/wh, yellow, green, red, r-cF, G-cF.
coL.D: Font colour for distance
coL.F: Font colour for flow
coL.P: Font colour for pressure
u
Select [cFH.x] and [cFL.x] and set the limits for the colour change:
cFH.D: upper limit for distance
cFL.D: lower limit for distance
cFH.F: upper limit for flow
cFL.F: lower limit for flow
cFH.P: upper limit for pressure
cFL.P: lower limit for pressure