CAN in the PDM360
CAN POUs to CANopen
249
Add and configure CANopen slaves
CANopen slave: Tab [CAN parameters] ................................................................................... 249
Tab [Receive PDO-Mapping] and [Send PDO-Mapping].......................................................... 251
Tab [Service Data Objects] ....................................................................................................... 252
8516
Next, you can add the CANopen slaves. To do so, please call the dialogue in the PLC configuration
[Insert] > [Append subelement] once more. A list of the CANopen device descriptions (EDS files)
stored in the directory PLC_CONF is at your disposal. By selecting the corresponding device it is
directly added to the tree of the controller configuration.
CANopen slave: Tab [CAN parameters]
1968
CAN parameters: Node ID
10036
The node ID is used to clearly identify the CAN module and corresponds to the number on the module
set between 1 and 127.
The ID is entered decimally and is automatically increased by 1 if a new module is added.