4 Electrical connection

The unit must be connected by a qualified electrician.

 

The national and international regulations for the installation of electri-

cal equipment must be adhered to.

 

Ensure voltage supply to EN 50178.

 

Disconnect power.

 

Connect the unit as follows:

Connector

 

pin 1 = L+

(pin 2 = not connected)

pin 3 = L-

pin 4 = load

Cable

BN = L+ 

BU =  L-

BK = load

Core colours: BN = brown, BU = blue, BK = black

5 Operation

 

Check whether the unit operates correctly.

• 

Dark-on switching units (OGH-DPKG): the output is switched / the yellow LED 

is lit when no object is detected. 

• 

Light-on switching units (OGH-HPKG): the output is switched / the yellow LED 

is lit when an object is detected. 

6 Maintenance, repair and disposal

 

Keep the front lens of the sensor free from soiling.

 

For cleaning do not use any solvents or cleaning agents which could damage 

the plastic material.