![IFM OGH Operating Instructions Manual Download Page 4](http://html1.mh-extra.com/html/ifm/ogh/ogh_operating-instructions-manual_4052099004.webp)
4
4 Installation
►
Align the diffuse reflection sensor to the object to be detected and secure it to
a bracket�
The objects to be detected should move
transversely to the lens of the sensor� In case
of other directions of movement it should be
tested before whether the switching function is
guaranteed�
5 Electrical connection
The unit must be connected by a qualified electrician�
►
The national and international regulations for the installation of
electrical equipment must be adhered to�
►
Ensure voltage supply to EN 50178�
►
Disconnect power�
►
Connect the unit as follows:
5.1 PNP
Pin 1 = L+ (10...30 V DC)
Pin 3 = L-
Pin 4 = load (PNP, 200 mA) / IO-Link
(Pin 2 = not connected)