background image

4

6 Settings

6.1 The sensor is to switch when the object is detected

1

 

Position the object.

 

 

Press [OUT on].

 

> The LED flashes.

2

 

Remove the object.

 

Press [OUT off].

 

> The LED goes out. The programming is finished.

6.2 The sensor is not to switch when the object is detected

 

► Position the object (see figure 1) and press [OUT off] for 2 s.

 

► Remove the object (see figure 2) and press [OUT on].

The setting can also be carried out first without object and then with object.

6.3 Setting of the maximum sensitivity

 

Interrupt the light beam.

The sensor is to switch when the object is detected.

 

First press [OUT on], then [OUT off].

The sensor is to switch when the object is not detected

 

First press [OUT off], then [OUT on].

6.4 Programming unsuccessful

 

>

The yellow LED flashes quickly (8 Hz).

•  Insufficient difference in measurements.
• 

Max. programming time (15 min.) exceeded.