3  Functions and features

The unit is used as an optical distance sensor�

3.1  Applications

•  The optical distance sensor measures distances between 0�03 and 2 m�
•  It has a background suppression of up to 20 m�
•  The switching outputs are complimentary�

The distance between the sensor and the background must be limited 

to max� 20 m by the customer� Otherwise the measured value may be 

ambiguous. → 4.1 Installation conditions

4  Installation

4.1  Installation conditions

 

Install the unit so that the object to be detected is within a measuring range of 

0�03���2 m�

Any object between the set switch point and a distance of 20 m from the sensor is 

suppressed�

Reflecting objects in the direct beam path of the sensor - also in the range 

> 20 m – are to be avoided by the customer� Otherwise the measured 

values may be ambiguous�

5  Operating and display elements

1:  LED green: operation

2:  LED yellow: switching status

3:  3-digit alphanumeric display

4:  Range +

5:  Range -

Summary of Contents for O5D10 Series

Page 1: ...Operating instructions Optical distance sensor O5D10x 80284255 00 04 2019 UK...

Page 2: ...5 4 1 Installation conditions 5 5 Operating and display elements 5 6 Electrical connection 6 7 Settings 7 7 1 The sensor is to switch when the object is detected 7 8 IO Link 7 8 1 General information...

Page 3: ...rmative requirements to be provided to the operator and user of the system This documentation must contain all necessary information and safety instructions for the operator the user and if applicable...

Page 4: ...ecified herein may result in hazardous radiation exposure Damage to the retina is possible Do not stare into the laser beam Apply the enclosed labels laser warning in the immediate vicinity of the uni...

Page 5: ...lue may be ambiguous 4 1 Installation conditions 4 Installation 4 1 Installation conditions Install the unit so that the object to be detected is within a measuring range of 0 03 2 m Any object betwee...

Page 6: ...lation of electrical equipment must be adhered to Voltage supply according to EN 50178 Disconnect power Connect the unit as follows DC PNP 4 3 2 1 4 OUT1 normally open IO Link 2 OUT2 normally closed D...

Page 7: ...communication interface which requires an IO Link capable module IO Link master for operation The IO Link interface enables direct access to the sensor values and parameters and provides the possibil...

Page 8: ...when the switching output is switched The detected distance value is shown in the display 9 1 Electronic lock The unit can be locked electronically to prevent unintentional settings On delivery the un...

Page 9: ...he measuring range 2500 mm OFF ON ERP Plausibility e g object too fast unchanged unchanged SC Short circuit at the switching output 10 Maintenance repair and disposal Keep the front pane of the sensor...