21
3D camera O3X1xx
UK
6.4 Edit Mode Object
The device will not distinguish between edit and run mode. The application will always behave as in
run mode. As soon as a session is opened the application can immediately be edited.
factoryReset
Method name
factoryReset
Description
Resets all configurations to factory settings
Input parameters
none
Output parameters
Empty string (compatibility with classic XmlRPC-client)
changeNameAndDescription
Method name
changeNameAndDescription
Description
Changes the name and the description of the application.
Input parameters
1. Application index :int
2. New name of the application: string (utf8, max. 64 character)
3. New description of the application: string (utf8, max. 500 character)
Output parameters
Empty string (compatibility with classic XmlRPC-client)
6.5
Device Config Object
activatePassword
Method name
activatePassword
Description
Sets a password and activates it for the next edit session.
Making this change persistently requires to call "save" on device
config.
Input parameters
Password: string
Output parameters
Empty string (compatibility with classic XmlRPC-client)
disablePassword
Method name
disablePassword
Description
Disables the password protection.
Making this change persistently requires to call "save" on device
config.
Input parameters
none
Output parameters
Empty string (compatibility with classic XmlRPC-client)
save
Method name
save
Description
Stores current configuration in persistent memory.
If this is not called after changing device parameters (via
setParameter), changes will get lost on reboot.
Input parameters
none
Output parameters
Empty string (compatibility with classic XmlRPC-client)