1  Preliminary note

This document is intended for specialists� These specialists are people who are 

qualified by their appropriate training and their experience to see risks and to 

avoid possible hazards that may be caused during operation or maintenance of 

the device� The document contains information about the correct handling of the 

device�
Read this document before use to familiarise yourself with operating conditions 

and installation� Keep this document during the entire duration of use of the 

device�
For a detailed description of the device please read the operating instructions and 

the programming manual�

1.1  Symbols used

Instructions

>

Reaction, result

[…] Designation of keys, buttons or indications

Cross-reference

Important note 

Non-compliance may result in malfunction or interference�

Information 

Supplementary note

1.2  Warning signs used

 

NOTE 

Warning of damage to property�

Summary of Contents for O3D3 Series

Page 1: ...Brief instructions 3D camera O3D3xx 80271111 00 11 2017 UK...

Page 2: ...used 3 1 2 Warning signs used 3 2 Safety instructions 4 2 1 Safety note 4 3 Functions and features 4 4 Items supplied 5 5 Accessories 5 6 Installation 6 6 1 Mounting accessories 6 7 Electrical connec...

Page 3: ...vice Read this document before use to familiarise yourself with operating conditions and installation Keep this document during the entire duration of use of the device For a detailed description of t...

Page 4: ...turer or by a person authorised by the manufacturer 2 1 Safety note NOTICE IR light emitted from this product Classification acc CEI IEC 62471 2006 Exempt group 3 Functions and features The O3D3xx 3D...

Page 5: ...n domestic areas The camera may only be used under the environmental conditions specified in the data sheet 4 Items supplied O3D3xx 3D camera Brief instructions The device is supplied without installa...

Page 6: ...he nut of the M12 Industrial Ethernet cable e g E11898 may corrode Use a cable with a high grade stainless steel nut for permanent use in wet areas 6 1 Mounting accessories Depending on the location a...

Page 7: ...ontact protection ATTENTION The unit must be connected by a qualified electrician Device of protection class III PC III Electric supply via PELV circuits only Electric supply must comply with UL61010...

Page 8: ...8 3 1 2 4 5 1 2 3 4 4 2 1 3 5 DC 24 V IN IN For the scope of validity cULus Minimum temperature rating of the cable to be connected to the field wiring terminals 70 C...

Page 9: ...witching output 1 ready 5 switching output 2 cascading Cover the unused sockets with protective caps E73004 Tightening torque 0 6 0 8 Nm You can find more information about the accessories at www ifm...