![IFM O2D54 Series Manual Download Page 11](http://html1.mh-extra.com/html/ifm/o2d54-series/o2d54-series_manual_4019158011.webp)
Object recognition sensor
O2D54x O2D55x
11
u
Observe the safety instructions for photobiological safety. (
The internal and external lighting is switched on 500 µs before the image is taken. Switching on
prematurely does not affect the brightness of the captured image.
w
Example: With an integration time of 100 µs, the lighting is switched on for 600 µs.
4.5.1 O2D54x
The device has RGBW lighting, which can be switched between the lighting colours red, green, blue
and white. Only one colour can be activated at a time, which applies to all internal lighting LEDs.
The optics of the device do not feature a band-pass filter.
The optics of the device and two of the four LEDs are equipped with polarisation filters.
u
Only activate the LEDs with polarisation filters to avoid direct reflection.
4.5.2 O2D55x
The device features an infrared illumination.
The optics of the unit feature a band-pass filter. Without the internal illumination, objects and contours
are difficult to detect. If possible, always use the internal illumination or an external illumination with a
suitable wavelength.
The device does not feature a polarisation filter.