5 Installation

u

Disconnect the power of the machine before installation.

The unit can be mounted in a horizontal position or with the connectors facing downwards.
Installation with the connectors facing upwards is not permitted.

The unit must be fixed with the rear facing the mounting surface.

ATTENTION

Higher shock > IK07

w

Damage possible
Protection rating and electrical protection might be impaired

u

If necessary, the system creator must take external measures to protect the device
depending on the requirements of the corresponding application.

u

Replace damaged units, otherwise the technical data and safety will be impaired.

74

Fig. 1: Holes for mounting

u

Use 2 M5x30 cylinder head bolts to fix the unit on an even surface.
Tightening torque: 2.2 Nm

5.1 Mounting the antennas

u

When mounting the antennas in vehicles avoid the vicinity of fuel tanks, vessels with explosives or
insufficiently screened electronic components (→ 2 Safety instructions).

u

Position the antennas so that a permanent distance of min. 0.2 m from people is ensured during
operation.

u

Do not install the antennas in closed metal constructions such as the driver's cab.

u

To reliably receive the GPS signals, position the GPS antenna with unrestricted access to the sky.

u

Please observe the antenna manufacturer’s notes.

Stable data transmission requires a good antenna signal. In case of problems change the
position of the antennas or the mobile equipment if necessary.

GB

Summary of Contents for mobileIoT CR3145

Page 1: ...Operating instructions mobileIoT gateway CR3145 11365922 00 03 2021 GB...

Page 2: ...vigation satellite system 9 4 6 1 Automatically send GNSS data to the mobileIoT platform 11 4 7 Energy management 11 4 8 Device status 12 4 9 Compatibility mode 13 5 Installation 15 5 1 Mounting the a...

Page 3: ...ctions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings us...

Page 4: ...e If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caus...

Page 5: ...The unit enables wireless transfer of CAN data of a vehicle or machine according to the GSM and UMTS standards GPRS EDGE and HSPA are supported It is also possible to receive and transmit GNSS positi...

Page 6: ...rk with the best transmission speed and automatically switches to it The mobile radio interface supports bidirectional data exchange in the mobile network 4 2 eSIM card The unit is equipped with an em...

Page 7: ...Raw value of the analogue input measure ment Volt No filtering applied Analogue input 2 0x546F 0x15 R32 ro Pin 5 of the 14 pin Micro Timer II connector Raw value of the analogue input measure ment Vo...

Page 8: ...t byte Length bytes Type Object IO BaseID 0x00 0 4 R32 IO clamp 30 voltage 4 4 R32 IO clamp 15 voltage IO BaseID 0x01 0 4 R32 Analogue input 1 4 2 S32 IO device temperature 4 5 Accelerometers and gyro...

Page 9: ...CAN messages COB ID Start byte Length bytes Type Object Movement BaseID 0x00 0 4 R32 Acceleration X axis 4 4 R32 Acceleration Y axis Movement BaseID 0x01 0 4 R32 Acceleration Z axis 4 4 R32 Gyroscope...

Page 10: ...ference point before logging the position The flag remains on the written value until the position has been recorded It is then re set to 0 The unit can send this data via the CAN interface The config...

Page 11: ...his time has elapsed the logged file is closed and trans mitted to the server Set this value to 0 to deactivate the period All data available in the respective device mode are sent via the CAN1 interf...

Page 12: ...eriod in sleep mode the unit automatically wakes up and changes to standard mode This function is only active with a value 0 Power manage ment accel wake up force 0x3333 0x36 R32 rw Force in g If the...

Page 13: ...1 mobileIoT server TCP connection active 3 1 U8 Current network mode 4 2 U16 State machine error code 6 1 U8 Current connection mode 0x00 cloud logging mode 0x01 reserved 0x02 real time mode 0x03 IoT...

Page 14: ...em result 8 fatal error 9 initialisation 10 Internet connection active 11 mobileIoT server TCP connection active 3 1 U8 File transfer receive indication 4 1 U8 File transfer transmit command 5 1 U8 SM...

Page 15: ...safety will be impaired 74 Fig 1 Holes for mounting u Use 2 M5x30 cylinder head bolts to fix the unit on an even surface Tightening torque 2 2 Nm 5 1 Mounting the antennas u When mounting the antennas...

Page 16: ...1 5 analogue input 2 6 analogue input 3 7 digital output 8 digital output clamp 15 input ignition signal 9 factory setting 2 input 10 Not connected 11 Not connected 12 Not connected 13 CAN1_H CAN int...

Page 17: ...e operating status of the active connections The different colours are displayed according to priority from 5 low to 1 high If several operating states are active at the same time the STATUS LED alway...

Page 18: ...ata transfer in real time mode STATUS ON Initialisation after power on STATUS ON A configuration update is carried out via the ifm mobileI oT data portal STATUS ON A remote firmware update is carried...

Page 19: ...tivated the unit an mobileIoT data contract will be concluded After successful registration and activation the unit establishes a connection to the ifm mobileIoT data portal and enables bidirectional...

Page 20: ...e is restored All recorded data and settings are deleted The factory configuration is retained To carry out the factory reset via the CAN interface CANopen software e g maintenance tool and a communic...

Page 21: ...fm in case of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the devic...

Page 22: ...rtal that processes applies the data mobileIoT platform The complete cloud solution including backend mobileIoT server infrastructure frontend for the machine management portal mobileIoT suite and dat...

Reviews: